Installation instruction for radial blowers for areas subject to gas and dust explosion hazards
2.2
Non-designated uses
Non-designated and hazardous uses specifically include
conveying of explosive or combustible media in zone 20 and zone 0; the blower may
only be used in zones 1, 21 and 2, 22 with a corresponding marking on the type plate;
conveying abrasive media;
conveying without a suitable intake protective screen;
operation without a motor cut-off switch;
use in underground mining operations;
any other use that deviates from the designated uses, and which will result in a
hazardous condition.
Safety
3
3.1
Basic safety instructions
Klein blowers are designed and produced in accordance with generally accepted technology,
occupational and accident prevention practices and in accordance with the requirements of
the ATEX- directive for machines and protective systems for the designated use in explosive
environments, as well as the requirements of the Machine and Product Safety Act [GPSG or
equivalent other national regulations]. They correspond to the state of the art.
Nevertheless, blowers in operation can be the source of hazardous conditions, especially
when hazardous conditions are created as a result of
inappropriate use or
non-designated use
.
For this reason, all instructions for the use of the blower must be adhered to.
07/2019 KARL KLEIN Ventilatorenbau GmbH
GB
Page 10