3.2.2.
Interfaces Terminal Block
The terminal block accommodates RS485 serial interface and input/output lines.
Table 6. Interface Connector Pin Assignment
Pin
1
GPIO1 contact
2
GPIO2 contact
3
GPIO3 contact
4
GPIO4 contact
5
GPIO5 contact
6
GPIO6 contact
7
GPIO7 contact
GND – negative supply voltage input/output
G
VCC – positive supply voltage input/output
V
Shield – signal wire shield contact
S
B
Signal B of RS485 interface
A
Signal A of RS485 interface
Figure 6. Interface Connector
Purpose
14