PCW-1331-US-ASB (19010) Installation Manual ® Advanced Clean 100 SpaLet Bidet Seat Model: 8017A60GRC Thank you for purchasing this product. Installation Procedure ● Carefully read this 1 Mounting the SpaLet Bowl installation manual to install this product correctly. CAUTION ↓ ● Be sure to test operation 2 Attaching the Water Shutoff after installation has been completed.
This manual consists of two parts; the first part contains safety precautions and descriptions of the Hold the plug or socket when connecting procedures when installing the SpaLet, and the or disconnecting the power plug or socket. second part contains visual installation methods. If the plug or socket is connected or Please use this manual in reference to each part.
Page 3
Do not attach the product to any water source If the water is expected to be frozen, other than potable water. drain the water out from the product. It may cause electric shock, fire and skin Failure to do so may cause fire, water inflammation due corrosion of electronic parts leakage, and/or flooding due to damage inside the seat unit.
POWER SUPPLY INSTALLATION POSITION OF THE REMOTE CONTROL Install the cord and outlet according to the On the left side On the right side specifications below. 1300 mm (51-3/16") The power distribution work should be done by an electrical contractor. ● Use an AC120V power supply with a consumption rating. If the product is used with other electric appliances, set the corresponding number of outlets. ● The wiring should be appropriate for the rated power consumption.
FIRMLY FIX THE WATER SUPPLY PIPE An impact applied to the hose due to high water pressure may cause vibrations. Fix the water supply pipe firmly so that it does not loosen. There is a danger vibration or flooding. TECHNICAL DATA Rated voltage AC120V 50/60Hz Rated power consumption...
Page 6
Parts names Upper body sensor Points of caution Flush button Remote control Product No. receiver SpaLet body indicator SpaLet lid Remote Control Seat unit Lower body sensor Side cover Nozzle shutter Power plug (with ground fault protected) Left side Inside the nozzle (when facing the shutter SpaLet body) Water shutoff valve Open/close knob Strainer Deodorizing filter Water SpaLet supply hose SpaLet Nozzle...
Page 7
Installation Procedure Mounting the SpaLet Bowl Attaching the water shutoff valve [See Note 2-1] 1. Remove the open/close knob 2. Affix the water shutoff valve to the water supply pipe. <Floor water supply> Open/close knob Perform this step after finishing the wall and floor. Attach the sealing material (sealing tapes) to the threaded section. Wall * Hook the tool on the hook setting (hex) on Water supply inlet Metal tool setting the water shutoff valve, and fasten it. (Hex) Approx. [See Note 2-2] 10°...
Page 8
Mounting the Seat Unit 3. Affix the seat unit. Installation diagram ① Place the washers (two) and spring washer over each fixing bolt, and affix the nut. ② Fasten the nut by hand. [See Note 3-3] Securing bolt Washers (x2) Washers Spring washer (x2) Spring washer Hexagonal nut Hexagonal nut ③ Align the tip of the SpaLet lid to the tip of the SpaLet bowl. 1. Remove the protective cap and tape. [See Note 3-1] The edge of <Rear of seat unit> <SpaLet bowl> the SpaLet Protective cap bowl is seen.
Connecting the Water Supply Hose <Seat Unit End> Installation diagram Seat unit water Protective cap supply inlet Do not apply excessive force when connecting the water Clip supply hose. (Gray) O-ring Water supply hose 1. Install the water supply hose to the [Note 4-1] seat unit. ● Remove the cap on the water supply hose ① Remove the protective cap.
Page 10
Connecting the Water Supply Hose <Water Shutoff Valve End> O-ring Installation diagram Clip (white) <Floor water supply> <Wall water supply> Water shutoff valve Clip (white) Clip (white) Water shutoff valve Water Water Water shutoff supply hose supply hose [See Note 5-1] valve 1. Install the water supply hose to the [Note 5-1] water supply inlet.
Connecting to the Power Supply 1. Connect the power plug to the outlet. WARNING Ensure the electrical outlet to which Power plug the power cord is connected is properly grounded, as failure to do so GROUND may cause electric shock, etc. 2. Check that the power is on. Confirm that the power indicator on the seat unit are illuminated. ● Flush button (indicator) Power indicator -11 EN-...
Positioning and Mounting the Remote Control ● Remote control installation position ● Sit on the SpaLet seat and ensure the installation position. [See Note 7-1] Install the remote control to a position where Temporarily install the remote control to the target position, the user can reach and operate it.
[Note 7-1] [Note 7-2] ● Ensure to install the batteries in the correct ● Ensure that there is enough space above the direction (note the negative and positive). remote control installation position to allow ● Do not mix old and new batteries. easy removal and mount of Remote control space ●...
Mounting the Side Cover ③ Push the center of the side cover to secure the 1. Attach the side covers on both sides. [See Note 9-1], [See Reference 9-1], “Velcro fastener” firmly. [See Reference 9-2] ① Insert the “clip” on the upper side of the side cover into the “clip holder” on the SpaLet bowl Velcro fastener ② Align the lines of the SpaLet bowl and the side cover, and attach the side cover to the “Velcro fastener” on the lower side of the SpaLet bowl. Clip holder Clip holder Clip Side cover ① Clip ② Side cover Velcro fastener [Note 9-1] ●...
Page 15
If the water does not flow well, clean the strainer. (1) Close the water shutoff valve to stop the water supply. Water shutoff valve Close [See Note 10-1] (2) Press the [FLUSH/FULL] button or press the flush button on the SpaLet body. * Wait approximately 20 seconds. Open/close knob * Drain the water and remove the water pressure inside the toilet body. (3) Remove the side cover on the left (when facing the SpaLet Side cover body). (4) Rotate and remove the strainer on the lower left when ②...
Page 16
When multiple bidets are installed: When multiple bidets are installed, a bidet in other booth may also respond to the signal and malfunction. To prevent this, you can change the signal using the remote control unit you purchased. Change both the emitting signal (remote control unit) and receiving signal (bidet body). 1. Changing emitting signal 2. Changing receiving signal Signal Operation Button Battery Mark (remote control unit) (bidet body) Number No. of Flashes Signal 1 Water Temp Once (1) Remove the batteries from (1) Remove the power plug of Signal 2 Seat Temp Twice the remote control unit. the bidet for which the signal is Signal 3 Power save Three times to be changed. Signal 0 Nozzle Cleaning Four times (2) Refer to the signal table...
Need help?
Do you have a question about the 8017A60GRC and is the answer not in the manual?