Maintenance
The Daikin One Home Air Monitor requires very little maintenance.
However, periodic inspection and cleaning of the air passageways
in the sensor probe will help to keep the detection sensors and
surfaces free of particles which, if left to build up, could cause
inaccurate reporting of the airborne particulates in the home's air.
CAUTION:
If you are not a qualified electrician of HVAC technician, or are not
comfortable and/or familiar with electrical power supplies, contact
your HVAC dealer to service this monitor.
To clean the Daikin One Home Air Monitor, first remove power
from the sensor probe by disconnecting the 24V supply wire from
its transformer.
Carefully pull the sensor probe out of ductwork, but leave the
mounting plate in place. Once the sensor probe is free of the
ductwork, carefully inspect the two passageways in the probe for
any visible particulate buildup on the internal surfaces.
If there is nothing visible, carefully reinsert the sensor probe
into the hole in the mounting plate just until you hear a
slight "click" . Do not push the sensor probe in further than
Our continuing commitment to quality products may mean a change in specifications without notice.
4
©2020
this "click" position. Reattach the supply of 24V power to
the sensor probe. When the sensor probe's LED light turns
solid blue (not flashing), then the device is back online
and operating.
If there is visible debris collected on the internal surfaces, take a
cotton swab that has been wet slightly with isopropyl or rubbing
alcohol and very gently wipe over the internal surfaces of the
sensor probe to remove the debris. Carefully reinsert the sensor
probe into the hole in the mounting plate just until you hear a
slight "click" . Do not push the sensor probe in further than this
"click" position. Reattach the supply of 24V power to the sensor
probe. When the sensor probe's LED light turns solid blue (not
flashing), then the device is back online and operating.
If you have any questions or concerns about this device's
maintenance, please call 1-855-DAIKIN1 for assistance.