Electronic transmitter providing unscaled, scaled & optional 4-20 ma outputs

Advertisement

Quick Links

®
Recordall
Electronic Transmitter
Installation &
Model RET™
Providing Unscaled, Scaled &
Operation Manual
Optional 4-20 mA Outputs
RET-IOM-1
BadgerMeter,Inc.
P/N 59322-033
2-02
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Recordall RET and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Badger Meter Recordall RET

  • Page 1 ® Recordall Electronic Transmitter Installation & Model RET™ Providing Unscaled, Scaled & Operation Manual Optional 4-20 mA Outputs RET-IOM-1 BadgerMeter,Inc. P/N 59322-033 2-02 ®...
  • Page 2: Scope Of This Manual

    The RET is equipped with an LCD digital display that can with other Badger Meter products. An internal lithium bat- be calibrated in either gallons, cubic feet, cubic meters, liters or imperial gallons. Using a magnet the product allows the tery is used to power the display .
  • Page 3: Installation Instructions

    Installation Instructions insertion operation may require significant force to displace The following instructions are to assist you in the connection the excess grease from the connector cavity. process of the RET™. Keep all parts clean prior to assembly. Any dirt or water within the connector enclosure can cause corrosion 3) With the connector halves forced together, turn the locking band of the contacts which will reduce connector life.
  • Page 4: Operation

    C. The example below shows a 3" Turbo Se- To change the ries meter calibrated in gallons. display, touch Recordall magnet here Electronic Badger Meter Transmitter 64001-002 ® Digital & 4-20 mA Outputs 0 450 TURBO 0501 Test mode: This screen is identical to the totalization screen except for the resolution.
  • Page 5: Programming Instructions

    Scaled pulse resolution: This screen uses the unit of mea- When an alarm occurs an error code displayed. The key for sure and the six digit display to show the amount of con- each alarm is the first number after the EC. Error codes are listed sumption that one scaled output pulse represents.
  • Page 6 move the pointer to the desired box. Click the left mouse button to place the cursor in the box. Use the backspace key to erase the existing number and use the keyboard to input a new number. After the parameters are chosen, press the “Program Transmit- ter”...
  • Page 7 Note: When not being read or programmed the RET™ should be number between 50% and 120% of the default flow rate. If a set disconnected from the Programmer. This will keep the 9 volt bat- point value is chosen that is not in the accepted range the user tery in the RET Programmer from being drained.
  • Page 8: Troubleshooting

    Ctrl+Alt+Delete keys simultaneously and shut off the appropriate Verify the 9 pin cable connection between the RET Pro- applications. grammer and the computer. Verify the correct COM port is being used. The computer screens of the RET™ Programmer can be printed Verify that all applications used for the selected COM to provide a copy of the parameters.
  • Page 9 This chart lists all the settings or possible settings for the RET™ by meter model. The data in the default columns indicates the factory settings of the unit, unless otherwise specified by the customer. RET™ FLOW RATE AND RESOLUTION CHART RET™...
  • Page 10 RET™ FLOW RATE AND RESOLUTION CHART RET™ FLOW RATE AND RESOLUTION CHART RET™ FLOW RATE AND RESOLUTION CHART RET™ FLOW RATE AND RESOLUTION CHART RET™ FLOW RATE AND RESOLUTION CHART Meter Meter Model Model Meter Meter Units Units Default Default Minimum Minimum Default...
  • Page 11 RET™ FLOW RATE AND RESOLUTION CHART RET™ FLOW RATE AND RESOLUTION CHART RET™ FLOW RATE AND RESOLUTION CHART RET™ FLOW RATE AND RESOLUTION CHART RET™ FLOW RATE AND RESOLUTION CHART Meter Meter Meter Model Model Model Meter Meter Meter Units Units Units Units...
  • Page 12 Please see our website at www.badgermeter.com BadgerMeter,Inc. for specific contacts. P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax: (888) 371-5982 www.badgermeter.com Copyright © Badger Meter, Inc. 2002. All rights reserved, all data subject to change without notice. ®...