This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50%
*
Particulate Class lll
85%
Contaminant
NSF Reduction
Reduction
Requirements
Lead:@ pH 6.5
0.01mg/L
Lead: @ pH 8.5
0.01mg /L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
p-dichlorobenzene
0.075 mg/L
O-Dichlorobenzene
0.60
Toxaphene
0.003
Ethyl Benzene
0.70
1,2,4- trichlorobenzene 0.07
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-L200V: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement filter L200V /NL120V, part
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.
Model WF-NL120V: Change the water filter every
6-9 months. Use replacement filter L200V / NL120V, part
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
*
Class Ill particle size: > 5 to < 15 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.
14

PRODUCT DATA SHEETS

Base Grille Water Filtration System
Model WF-L200V Capacity 200 Gallons (757 Liters)
Model WF-NL120V Capacity 120 Gallons (454 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene, O-Dichlorobenzene, Toxaphene, Ethyl Benzene,
1,2,4-trichlorobenzene and against NSF/ANSI Standard 42 for the
reduction of Chlorine Taste and Odor and Particulate Class III.
Average
Influent Challenge
Influent
Concentration
1.9 mg/L
2.0 mg/L ± 10%
49333/mL
At least 10,000 particles/mL
Average
Influent Challenge
Influent
Concentration
0.14 mg/L
0.15 mg/L ± 10%
0.15 mg/L
0.15 mg /L ± 10%
0.0059 mg/L
0.006 mg/L ± 10%
0.0054 mg/L
0.006 mg /L ± 10%
0.0157 mg/L
0.015 mg/L ± 10%
0.210 mg/L
0.225 mg/L ± 10%
1.84
1.8 ± 10%
0.0143
0.015 ± 10%
2.00
2.1 ± 10%
0.232
0.21 ± 10%
Maximum
Average
Effluent
Effluent
0.07 mg/L
0.06 mg/L
640/mL**
312/mL
Maximum
Average
Effluent
Effluent
0.0014 mg/L
0.0011 mg/L
0.0069 mg/L
0.0042 mg/L
0.0009 mg/L
0.0004 mg/L
0.0007mg /L
0.00043 mg/L
0.002 mg/L
0.00083 mg/L
0.0005 mg/L
0.0005 mg/L
0.20
0.0418
0.0012
0.0010
0.40
0.085
0.0041
0.0016
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited

warranty.

Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum%
Average%
Reduction
Reduction
>75%
>75%
98.7%
99.0%
Minimum%
Average%
Reduction
Reduction
99.00%
99.21%
95.40%%
97.20%
84.74%
93.22%
87.03%
92.03%
87.26%
94.71%
99.76%
99.76%
89.13
97.73
91.60
93.00
80.00
95.75
98.23
99.31
City or Well
30 - 120 psi (207 - 827 kPa)
° - 100°F (0.6° - 37.8°C)
33
0.5 GPM (1.9 L/min.) @ 60 psi.