Standard Interior Water Filtration System Model WFI-NL200/NL200
Capacity : 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance
U.S. EPA
Reduction
MCL
Chlorine, Taste/Odor
N/A
Cyst Interior Water Filtration System Model WFI-NLC200/NLC200
Capacity: 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance Reduction
U.S. EPA
Aesthetic Effects
MCL
Chlorine Taste/Odor
N/A
Particulate
N/A
Contaminant
U.S. EPA
Reduction
MCL
Cyst
99.95%**
Turbidity
N/A
Lead: @ pH 6.5
0.015 mg/L
Lead: @ pH 8.5
0.015 mg/L
It is essential that operational, maintenance, and filter
replacement requirements be carried out for this product to
perform as advertised.
Model NL200 Change cartridge at least every 6-9 months.
Use replacement cartridge NL200, part# 8171413. 2002
suggested retail price of $29.95 U.S.A./$39.95 Canada.
Prices are subject to change without notice.
Model NLC200 Change the cartridge at least every 6-9
months. Use replacement cartridge NLC200, part# 8171414.
2002 suggested retail price of $39.95 U.S.A./$49.95 Canada.
Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction
may be used on disinfected water that may contain
filterable cysts.
*
Test requirement is at least 100,000 particles/ml of AC Fine Test Dust.
Cyst performance is % reduction based on NSF Standard 53.
**
Test requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water
***
conditions.
® NSF is a registered trademark of NSF International.

PRODUCT DATA SHEETS

Tested and certified by NSF International against ANSI/NSF
Standard 42 for the reduction of Chlorine (Class I), Taste and Odor.
Average
Maximum
Influent
Effluent
2.0 mg/L
N/A
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Average
Maximum
Influent
Effluent
1.9 mg/L
N/A
108,667/mL*
N/A
Average
Maximum
Influent
Effluent
157,750/mL
55/mL
26 NTU
0.5 NTU
0.160 mg/L***
0.011 mg/L
0.158 mg/L***
0.011 mg/L
Average
Minimum %
Effluent
Reduction
0.02 mg/L
N/A
Average
Minimum %
Effluent
Reduction
0.06 mg/L
N/A
45/mL
N/A
Average
Minimum %
Effluent
Reduction
1.0/mL
99.9987%
0.1 NTU
98.9%
0.001 mg/L
93.5%
0.001 mg/L
92.1%
Refer to the "Assistance or Service" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited

warranty.

Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Average %
NSF Test
Reduction
Number
99%
994715
Average %
NSF Test
Reduction
Number
97%
994707
99.96%
994711
Average %
NSF Test
Reduction
Number
99.9996%
994710
99.5%
994710
99.4%
994708
99.3%
994709
City or Well
30 - 120 psig (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)
23