Wired Probe System - Troubleshooting Guide
Introduction
Wired Probe System - Troubleshooting Guide
Page 1 of 7 pages
1. OMP40 work probe: A spindle-mounted
wireless probe that communicates with
an optical interface.
2. Work probe stylus: The part of the work
probe that touches parts during
measurement.
3. Tool probe stylus: The part of the tool
probe that tools touch during
measurement. Tools touch the top and
side of the stylus when the probe
measures tool length and diameter.
4. TS27R tool probe: The table-mounted
TS27R has no batteries or optical
interface. This is a wired probe.
5. Tool probe cable: This cable carries
signals from the tool probe to the CNC
control.
6. OMI Optical Machine Interface: The
wireless interface for the OMP40 work
probe. The OMI uses infrared light to
communicate with the CNC control and
switch the probe on or off.
7. OMI cable: This cable connects the OMI
to the CNC control.
Work probes for Wireless Probe System (WIPS) do
not work in the wired probe systems (VQCPS).
• The VCQPS work probe (P/N 60-0024)
has a square Haas logo.
• The WIPS work probe (P/N 60-0050) has
a round Haas logo.
LAST UPDATED: 02/14/2020

Advertisement

loading

Summary of Contents for Haas VCQPS

  • Page 1 CNC control. Work probes for Wireless Probe System (WIPS) do not work in the wired probe systems (VQCPS). • The VCQPS work probe (P/N 60-0024) has a square Haas logo. • The WIPS work probe (P/N 60-0050) has a round Haas logo.
  • Page 2 Wired Probe System - Troubleshooting Guide Work Probe Operation To power on the work probe, enter this program in MDI: M53; G04 P2.; Push [CYCLE START]. The LEDs on the work probe flash green when the probe is powered on and ready for use. When the probe stylus is touched, a “beep”...
  • Page 3: Symptom Table

    Wired Probe System - Troubleshooting Guide Symptom Table Page 3 of 7 pages...
  • Page 4 Wired Probe System - Troubleshooting Guide SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Alarm 1086 PATH Clear the obstruction and start again from a safe Protected Positioning Cycle only. OBSTRUCTED position. Insert the F code input and start again from a Alarm 1088 NO FEED Protected Positioning Cycle only.
  • Page 5 Wired Probe System - Troubleshooting Guide Batteries Corrective Action: Refer to WIRELESS INTUITIVE PROBE SYSTEM - WIPS - TROUBLESHOOTING GUIDE Interference Corrective Action: Refer to WIRELESS INTUITIVE PROBE SYSTEM - WIPS - TROUBLESHOOTING GUIDE Macros Corrective Action: The wired probe system uses RENISHAW VQCPS MACRO VERSION 1.9.
  • Page 6: Installation

    Wired Probe System - Troubleshooting Guide Settings Corrective Action: A procedure to verify the probe settings is included in the Renishaw Probes Installation guide. Refer to MILL - RENISHAW PROBES - INSTALLATION.  Note: Do not touch the stylus when you install the batteries. This can change the settings. To change the probe settings you move the stylus in a specified order.
  • Page 7 Wired Probe System - Troubleshooting Guide Calibration Corrective Action: The probes need to be calibrated anytime a stylus has been replaced, the table probe has been moved, or if the CNC control generates alarms during probe routines. Follow the procedure for calibrating the Table Probe and the Spindle Probe.