Wired Probe System - Troubleshooting Guide
SYMPTOM
POSSIBLE CAUSE
Alarm 1086 PATH
Protected Positioning Cycle only.
OBSTRUCTED
Alarm 1088 NO FEED
Protected Positioning Cycle only.
RATE
Alarm 1089 NO TOOL
G43 or G44 is not active before the cycle
LENGTH ACTIVE
is called.
Alarm 1091 FORMAT
Inputs are mixed, missing, or incorrectly
ERROR
formatted.
Interference from the work lights.
Alarm 1092 PROBE
Settings in the work probe are not
OPEN/UNEXPECTED
correct.
SURFACE FOUND
The surface of the part was not found.
Occurs if the probe is already triggered
before a move or triggered while
positioning the probe or tool.
Interference from the work lights.
Alarm 1093 PROBE
Settings in the work probe are not
FAIL/SURFACE NOT
correct.
FOUND
The surface of the part was not found.
Alarm 1099 BROKEN
This alarm occurs if a tool is out of user
TOOL
defined tolerance.
Bad Batteries.
The macros are corrupted.
Alarm 1101 PROBE
Settings in the work probe are not
STARTUP FAILURE.
correct
During probe start-up, the spindle must
reach a speed of 500 RPM.
The tool probe does not
The macros are corrupted.
beep/activate.
The OMI LEDs do not
The macros are corrupted.
turn green.
Incorrect
The probe is not calibrated.
measurements.
CORRECTIVE ACTION
Clear the obstruction and start again from a safe
position.
Insert the F code input and start again from a
safe position. Recommended protected
positioning feed rate is 120 in/min.
Edit the program and start again from a safe
position.
Edit the program and start again from a safe
position.
Adjust the work lights
Correct the settings.
Edit the program.
Clear faults and restart from safe position, check
if chips are trapped around probe eyelids
Adjust the work lights
Correct the settings.
Edit the program.
Replace defective tool and establish correct tool
offset value.
Replace the batteries.
Reload the macros
Correct the settings
Check that the spindle override is not active.
Possible faulty probe.
Reload the macros
Reload the macros
Calibrate the probe.
Page 4 of 7 pages