mishandled, or if the enclosure is broken, discontinue use and contact your care
provider.
Supplemental oxygen must not be used while smoking or in the presence of an
open flame.
Always make sure that the device is turned on and airflow generated before the
oxygen supply is turned on. Always turn the oxygen supply off before the
device is turned off, so that unused oxygen does not accumulate within the
device enclosure and create a risk of fire.
Sources of oxygen must be located more than 1 m from the equipment to avoid
the risk of fire and burns.
Do not perform any maintenance tasks while the device is in operation.
CAUTION
Use only compliant parts and accessories with the device. Non-compliant parts
may reduce the effectiveness of the treatment and/or damage the device.
Be careful not to place the device where it can be bumped or where someone is
likely to trip over the power cord.
Use only VentMed masks recommended by VentMed or by the prescribing
doctor with this device. Fitting the mask without the device blowing air can
result in rebreathing of exhaled air. Make sure that the mask vent holes are kept
clear and unblocked to maintain the flow of the fresh air into the mask.
Keep the device dry, clean and clear of anything (eg, clothes or bedding) that
could block the air inlet or cover the power supply unit.
Do not place the device on its side as water might get into the device.
Do not block the air tubing and/or air inlet of the device while in operation as
they could lead to overheating of the device.
Incorrect system setup may result in incorrect mask pressure reading. Ensure
the system is correctly set up.
Make sure that the water tank is empty before transporting the device.
When use the humidifier, please always place the device on a level surface
lower than your head to prevent the mask and air tubing from filling with water.
Leave the water tank to cool for ten minutes before handling to allow the water
to cool and to make sure that the water tank is not too hot to touch.
Do not use bleach, chlorine, alcohol, or aromatic-based solutions, moisturizing
or antibacterial soaps or scented oils to clean the device, the water tank or air
tubing. These solutions may cause damage or affect the humidifier