RHEEM THERMAL AIR SOURCE HEAT PUMP INSTALLATION, MAINTENANCE & SERVICE MANUAL
5.1 Thermostat Model
5.1.1 Machine Will Not Start
As a safety feature, the Heat Pump has a programmed time delay between provision
of power and unit start, usually a few minutes. Wait for this time delay before making
the following checks:
Check electrical supply to the unit is ON.
•
Check water flow
•
Check electrical for loose connections and wiring.
•
Check supply fuse.
•
Check thermostat is correctly set.
•
5.1.2 Storage Tank Will Not Heat
Check that the ejected air temperature is colder than incoming air. If so, this means
•
the unit is extracting heat from the air and transferring this to water.
Check that the evaporator and internal pipes sweating. This is evidence of heat
•
removal from the air, suggesting that the heater is working.
Check inlet louvres, outlet grill and condenser coil has satisfactory airflow and is not
•
clogged.
Check that thermostat is correctly set
•
Check that water pump is running
•
Check that inlet valves are not closed
•
Check ambient air temperature suits design standards
•
The temperature rise for a heat pump heating may seem slow but the unit is probably
working. Typically, heat pumps have a much lower KW per hour heat output capacity
than gas and will need to operate for more time to deliver the same heat transfer.