Electrical Connection - Whirlpool W10258095A Installation Instructions Manual

30" (76.0 cm) freestanding electric ranges
Table of Contents

Advertisement

Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range.
3. Remove plastic tag holding three #10-32 hex nuts from the
middle post of the terminal block.
6

Electrical Connection

Direct Wire
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
4. Add strain relief.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
Feed the power supply cord through the strain relief on
the cord/conduit plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
Use Phillips screwdriver to remove screws and rotate/
conduit plate 180º.
WARNING
Electrical Shock Hazard
A
A. UL listed strain relief - large opening
B. Small opening
A
A. Large opening
B. Small opening
B
B

Advertisement

Table of Contents