General Instructions; Installation - T&S B-1450-01 Installation And Maintenance Instructions Manual

Washdown stations
Table of Contents

Advertisement

Available languages

Available languages

General Instructions

Installation:

Note: Before installing valve flush out all
supply lines.
1. Screw no.8 into bottom of valve, use
Teflon Tape or pipe joint compound on
threads. Opening should face towards
front.
2. Screw no.7 into opening of no.8,
use Teflon Tape (Do Not Use Loctite
on threads, as no.7 may need to be
replaced at a later date.)
3. Mount no.1 to wall with bolts and
anchors (supplied by others), or other
appropriate means. No.2 are provided
by T&S Brass
anchor
7
1
bolt
close view of
no.1
installation
1
4. Connect supply lines to corre-
sponding inlets (cold side is marked
on no.1 casting).
1
7
8
7
3
6
close view of
4
no.6
installation
5. Mount no.6 at a convenient
location, using no.3, no.4 and no.5
provided.
6. Attach no.9 to bottom of no.8
(B-1450-01 / B-1451-01) or to bottom
of no.1 (B-1450 LT / B-1451-LT) with
Teflon Tape (No Loctite), tighten with
a wrench.
7. Attach no.10 to end of no.9.
8. Turn on water supply and check
for leaks.
hot side
cold side
inlet
inlet
6"
8"
5