  • Page 1 CLORADOR SALINO SALT WATER CHLORINATOR MANUAL DE USUARIO USER MANUAL 1 / 95 Manual BSONE-EVO v.2...
  • Page 2 Español ……………………………………….. 3 English …………………………………………49 2 / 95 Manual BSONE-EVO v.2...
  • Page 3 ANOTE EN LA SIGUIENTE FICHA LOS DATOS DE MATRICULA DEL EQUIPO QUE HA ADQUIRIDO Y QUE SE ENCUENTRAN EN LA ETIQUETA LATERAL DEL MISMO. ESTOS DATOS LE SERAN DE UTILIDAD SI DESEA REALIZAR ALGUNA CONSULTA A SU PROVEEDOR MODELO……………………………………………… REF. ………………………………………………….. TENSION…………………………………………….. NUM SÉRIE.………………………………………… 3 / 95 Manual BSONE-EVO v.2...
  • Page 4: Table Of Contents

    5.1- Limpieza de la célula de electrolisis ........................45 5.2- Comprobación y mantenimiento de la sonda ADVANCED ..................46 5.4- Comprobación y mantenimiento de la sonda Amperométrica (kit PRO/2) ............47 6 - GARANTÍA Y SERVICIO ............................48 4 / 95 Manual BSONE-EVO v.2...
  • Page 5: Descripción General

    (de 8 a 15 en función del uso), colaborando así con las políticas de conservación del medio ambiente y a la gestión y ahorro del agua. 5 / 95 Manual BSONE-EVO v.2...
  • Page 6: Características Técnicas

    Desconecte el equipo de la red antes de realizar cualquier operación de montaje o mantenimiento. Asegúrese de que la instalación eléctrica dispone de los elementos protección obligatorios (magnetotérmico diferencial) y que éstos funcionan correctamente. 6 / 95 Manual BSONE-EVO v.2...
  • Page 7: Preparación De La Piscina

    Para calcular la cantidad de sal a incorporar, multiplique los m3 totales de su piscina x la concentración recomendada en (Kg/m3). 7 / 95 Manual BSONE-EVO v.2...
  • Page 8: Equilibrio Químico Del Agua

    Es recomendable realizar un análisis en profundidad del agua al instalar un clorador salino. Parámetro Valor Mínimo Valor máximo CLORO LIBRE (mg/l) CLORO COMBINADO (mg/l) BROMO TOTAL (mg/l) BIGUANIDA (mg/l) ACIDO ISOCIANÚRICO (mg/l) <75 OZONO (vaso) (mg/l) 8 / 95 Manual BSONE-EVO v.2...
  • Page 9: Instalación Del Equipo

    • Es imprescindible una buena toma de tierra y usar un relé diferencial de máx. 30mA de sensibilidad. En caso de no disponer una toma de tierra de buena calidad, colocar una toma de tierra entre la célula de electrólisis y la sonda redox. KIT OPCIONAL 9 / 95 Manual BSONE-EVO v.2...
  • Page 10: Esquema De Conexionado Hidráulico

    3.2- Esquema de conexionado hidráulico 3.2.1- Equipos de la serie BSONE-EVO 1. De la piscina. 2. Filtración. 3. Cuadro eléctrico. 4. Bypass. 10 / 95 Manual BSONE-EVO v.2...
  • Page 11: 2- Kit Auto

    3.2.2.1- Despiece 1- Equipo BSONE-EVO 2- Tubo de aspiración (flexible) 3- Tubo de Inyección (rígido) 4- Filtro de aspiración (colocar en vertical en el fondo del recipiente de ácido) 11 / 95 Manual BSONE-EVO v.2...
  • Page 12 2- Colocaremos la brida (7) en la tubería tal y como se indica en el dibujo de conexión hidráulica. La brida (7) corresponde a la de la sonda de PH y se debe conectar, antes de la célula de electrólisis y después el filtro. 12 / 95 Manual BSONE-EVO v.2...
  • Page 13: 3- Kit Advanced (Redox)

    Esta sonda le permite ajustar el equipo en modo de funcionamiento AUTOMÁTICO. 3.2.3.1- Despiece 1-Sonda REDOX 2-Porta-Sonda 3-Brida 4-Líquido patrón 465mV 13 / 95 Manual BSONE-EVO v.2...
  • Page 14: 4- Kit Pro/2 (Sonda Amperométrica Para La Medida Del Cloro Libre)

    3.2.4.1-Contenido del Kit 3.2.4.1.1-Portasondas 3.2.4.1.2-Sonda de Cloro Libre: Este kit incluye: Sonda CC1 Membrana (incorporada en el cabezal) Tapón protector superior Electrolito ECC1.1/GEL Papel Abrasivo 14 / 95 Manual BSONE-EVO v.2...
  • Page 15 Cambio de electrolito: Cada 3-6 meses, en función de la calidad del agua 3.2.4.3- Instalación Por favor, siga atentamente las recomendaciones relativas a la instalación de la sonda para garantizar el buen funcionamiento de la misma. 3.2.4.3.1 Instalación hidráulica 15 / 95 Manual BSONE-EVO v.2...
  • Page 16 -Como alternativa, puede tomar la muestra en un punto previo al filtro de la piscina. En este caso, resulta imprescindible instalar un filtro especifico (de tipo 16 / 95 Manual BSONE-EVO v.2...
  • Page 17 3) Muy importante: Antes de roscar de nuevo el cabezal al cuerpo de la sonda, deberá retirar la anilla de silicona que cubre el pequeño orificio que se muestra en la imagen siguiente: 17 / 95 Manual BSONE-EVO v.2...
  • Page 18 Conecte el cable blanco a la entrada (+), indicada en la regleta con un punto rojo en su lateral derecho. Conecte el cable marrón a la entrada (-) Una vez realizada la conexión, cierre el tapón superior y apriete el prensaestopas. 18 / 95 Manual BSONE-EVO v.2...
  • Page 19 Nota: El tiempo de estabilización de la primera puesta en marcha puede resultar ligeramente superior a la habitual. En cualquier caso, se recomienda esperar por lo menos 3 horas antes de realizar una primera calibración de la sonda. 4) Calibración 19 / 95 Manual BSONE-EVO v.2...
  • Page 20 Kit PRO/2. Los periodos de mantenimiento son orientativos, ya que dependen de factores como la calidad del agua y del correcto mantenimiento de la instalación, en especial del funcionamiento y limpieza del sistema de filtrado. 20 / 95 Manual BSONE-EVO v.2...
  • Page 21: 5- Kit Sonda Ntc/1

    7) Instale la sonda nuevamente en el portasondas. Calíbrela de nuevo tras 2-3 horas de funcionamiento. 3.2.5- Kit sonda NTC/1 (OPCIONAL) para la medida de la temperatura del agua en los equipos BSONE-EVO 21 / 95 Manual BSONE-EVO v.2...
  • Page 22: 6-Kit Conductivity

    - Utilice un collarín de 1”1/4 (no suministrado) adecuado al diámetro de la tubería donde irá ubicado el sensor. 3.2.6.2.2-Conexión al equipo. Una vez instalado su sensor de conductividad, conéctelo a su equipo BSONE- EVO tal y como se indica a continuación: 22 / 95 Manual BSONE-EVO v.2...
  • Page 23 No se requiere un mantenimiento periódico en el sensor de conductividad. No obstante, si detecta que la lectura no es correcta, revise el cabezal de la sonda y revise que no presenta ningún cuerpo extraño. 23 / 95 Manual BSONE-EVO v.2...
  • Page 24: Esquema De Conexionado Eléctrico

    *activar la función FLOW SWITCH en menú de configuración ** para la conexión del kit PRO/2, consultar el apartado 3.5.2 de este manual. K1: Relé PH K4: Relé auxiliar LK2: Paro/Marcha (ver apartado 3.3.3.1) F1: Fusible 24 / 95 Manual BSONE-EVO v.2...
  • Page 25 230V en bornes de “filtro”, y cuando la bomba se detenga, la tensión en “filtro” sea de 0V. 25 / 95 Manual BSONE-EVO v.2...
  • Page 26 Atención: No superar nunca los 12A cuando utilice el relé auxiliar. Para corrientes mayores, complemente el circuito con un contactor. Tenga en cuenta que el relé es libre de potencial, por lo que deberá alimentar el circuito externamente. 26 / 95 Manual BSONE-EVO v.2...
  • Page 27 Puede controlar la bomba de filtración a través del relé auxiliar siguiendo el esquema siguiente: Debe tenerse en cuenta que el equipo debe configurarse en modo “paro- marcha”, tal y como se detalla en el apartado 3.3.2.1 27 / 95 Manual BSONE-EVO v.2...
  • Page 28: Puesta En Marcha Y Ajustes

    Cubierta(S) -> Switch N.A Programa OFF Cubierta(S) -> Switch N.C Timer, min Interr. Caudal (N)S Acido (Alkali) Menú reloj Alarma pH (S)N Alarma Cloro Reloj (ajuste de la hora) Alarma 22h-9h Menú Sal Calibración 28 / 95 Manual BSONE-EVO v.2...
  • Page 29 (modelos BSONE-EVO) y el estado del relé La 4ª línea muestra Menú (pulsando el botón OK se accede al menú) y la hora del reloj. Además, si se produce cualquier alarma o advertencia, esta será mostrada también en esta línea. 29 / 95 Manual BSONE-EVO v.2...
  • Page 30 ATENCION: Se le solicitará una contraseña si desea cambiar la configuración de algunas de las opciones de este menú. Esto previene al usuario de realizar cambios de forma accidental que puedan afectar al correcto funcionamiento del equipo. 30 / 95 Manual BSONE-EVO v.2...
  • Page 31 Seleccione este modo solamente si dispone de un kit sonda ADVANCED (Redox) o kit sonda PRO (Amperométrica). Si no dispone de sonda, el equipo se comportará de manera aleatoria y acabará por detenerse y mostrar un error. 31 / 95 Manual BSONE-EVO v.2...
  • Page 32 El tiempo diario de cloración se calculará a partir de este parámetro y de la temperatura del agua. Cada vez que se cambie el valor, al salir del menú, nos aparecerá en pantalla las horas de filtración mínimas que debe trabajar la bomba. 32 / 95 Manual BSONE-EVO v.2...
  • Page 33 Una vez activado el sistema de detección de cubierta, se le requerirá seleccionar el tipo de sensor de final de carrera que tenga instalado, ya sea normalmente abierto (n.o.) o normalmente cerrado (n.c.) 33 / 95 Manual BSONE-EVO v.2...
  • Page 34 Ácido: Seleccione este modo si va a inyectar minorador de pH en su piscina (modo por defecto) Alcalino: Seleccione este modo si necesita inyectar aumentador de pH en su piscina. 34 / 95 Manual BSONE-EVO v.2...
  • Page 35 Nota: Para modificar esta configuración, se requiere introducir la contraseña “1234”. 35 / 95 Manual BSONE-EVO v.2...
  • Page 36 650 mV. 700 mV es el valor apropiado para la mayoría de piscinas. Pulse el botón “OK” para confirmar el ajuste. No obstante, se recomienda determinar el valor de consigna más 36 / 95 Manual BSONE-EVO v.2...
  • Page 37 PPM que nos ha dado la medición DPD1. 4.1.6- Menú pH Este menú le permite el ajuste de los parámetros relacionados con el ajuste del pH de su piscina, y aparece únicamente en los equipos de la serie BSONE-EVO. 37 / 95 Manual BSONE-EVO v.2...
  • Page 38 Para calibrar la sonda, prepare un vaso con agua limpia. Retire la sonda del líquido de almacenaje, sacúdala para eliminar el líquido, agítela en el agua. Sacúdala de nuevo para eliminar el agua. Séquela con un paño limpio, sin frotar. 38 / 95 Manual BSONE-EVO v.2...
  • Page 39 Pulsando “OK” la indicación pasa alternativamente de “pH ON” (en marcha) a “pH OFF” (parado). Cuando el control de pH está parado, en la pantalla que muestra los parámetros la 3ª línea indica “pH:OFF”. 39 / 95 Manual BSONE-EVO v.2...
  • Page 40 Puede ver más detalles en las páginas 30 y 31 de este manual. 4.1.7.1- Marcha/Paro Efectúa un encendido / apagado manual del relé 4.1.7.2- Programa (1/24h) Permite una sola programación diaria de 0h a 23.59h 40 / 95 Manual BSONE-EVO v.2...
  • Page 41: Mensajes De Advertencia Y Alarmas

    Del mismo modo, mostrará una advertencia también en la 4ª línea, pero sin señal acústica ni detener el equipo. En este caso, el equipo puede seguir trabajando aunque le informa que debe tomar alguna acción correctiva. 41 / 95 Manual BSONE-EVO v.2...
  • Page 42: 1-Advertencias

    4.2.1.1-Mensajes de advertencia adicionales Valor En modo automático, la Ninguna. parpadeando sonda Redox o de cloro libre está estabilizando. Cuando la sonda está estable, el 42 / 95 Manual BSONE-EVO v.2...
  • Page 43: 2- Mensajes De Alarma

    Revise la conexión de la célula, y ABIERTO” que los cables y terminales de conexión encuentren perfecto estado Célula dañada Revise el estado de los electrodos completamente agotada de la célula, y sustitúyala si se observa algún daño mismos. 43 / 95 Manual BSONE-EVO v.2...
  • Page 44: Horas De Funcionamiento

    El equipo viene configurado de fábrica con un periodo de 4h. Si el agua de su piscina es muy dura, deberá bajar el valor de horas entre limpiezas, pero tenga en cuenta que la vida de la célula se verá reducida. 44 / 95 Manual BSONE-EVO v.2...
  • Page 45: 5- Mantenimiento

    Sumerja la célula en una solución de ácido clorhídrico, o bien de un producto comercial para limpieza de células de electrolisis (CELLCLEAN). No utilice objetos punzantes que dañarían la capa de titanio de los electrodos. 45 / 95 Manual BSONE-EVO v.2...
  • Page 46: Comprobación Y Mantenimiento De La Sonda Advanced

    Si una sonda se ha dejado secar puede regenerarse dejándola unas 12 horas en un vaso de agua, preferiblemente añadiéndole unas gotas de ácido clorhídrico. 46 / 95 Manual BSONE-EVO v.2...
  • Page 47: Comprobación Y Mantenimiento De La Sonda Amperométrica (Kit Pro/2)

    Reactivos DP-1 gastados Repetir medida DPD-1 con reactivos nuevos Lectura inestable Fallo en la conexión del Revisar conexiones sensor con el controlador 47 / 95 Manual BSONE-EVO v.2...
  • Page 48: Garantía Y Servicio

    Los gastos de envío correrán a cargo del propietario del equipo. Debe tenerse en cuenta que todas las reparaciones en garantía se realizarán en fábrica, o bien por un servicio técnico autorizado por BSV Electronic. 48 / 95 Manual BSONE-EVO v.2...
  • Page 49 THE EQUIPMENT YOU HAVE PURCHASED, WHICH ARE FOUND ON THE SIDE LABEL. THESE DATA WILL BE OF USE IF YOU WISH TO MAKE ANY ENQUIRY TO YOUR SUPPLIER MODEL……………………………………………… REF. ………………………………………………….. VOLTAGE…………………………………………….. SERIAL NUMBER.………………………………………… 49 / 95 Manual BSONE-EVO v.2...
  • Page 50 5.2- Checking and maintenance of the Redox probe ....................91 5.3- Checking and maintenance of the pH probe......................92 5.4- Checking and maintenance of the Amperometric probe ..................92 6 - GUARANTEE AND SERVICE ............................. 94 50 / 95 Manual BSONE-EVO v.2...
  • Page 51: General Description

    If the salt water chlorinator equipment is left to work permanently, it will not be necessary to change the swimming pool water for several years (8 to 15 depending on its use). You will therefore be collaborating with environment preservation policies and water management and saving. 51 / 95 Manual BSONE-EVO v.2...
  • Page 52: Technical Specifications

    Automatic restart in the event of supply failure. 1.3- Recommendations and safety precautions The equipment should always be installed by qualified staff. Disconnect the equipment from the mains before performing any assembly or maintenance operation. 52 / 95 Manual BSONE-EVO v.2...
  • Page 53: Preparing The Swimming Pool

    We recommend a concentration of 5Kg/m3 to offset small losses of salt occurring when cleaning the filter, the effect of rainfall, etc. To calculate the salt to be added, multiply the total m3 of your swimming pool x 5. 53 / 95 Manual BSONE-EVO v.2...
  • Page 54: Chemical Balance Of The Water

    Parameter Minimum Maximum Value Value FREE CHLORINE (mg/l) COMBINED CHLORINE (mg/l) TOTAL BROMIDE (mg/l) BIGUANIDE (mg/l) ISOCYANURIC ACID (mg/l) <75 OZONE (GLASS) (mg/l) OZONE (before) TURBIDITY (NTU) <1 54 / 95 Manual BSONE-EVO v.2...
  • Page 55: Installation Of The Equipment

    • A good earth connection is essential. Use a differential relay with max. 30mA of sensitivity. If a good quality earth connection is not available, place an earth connection kit between the electrolysis cell and the redox probe. OPTIONAL KIT 55 / 95 Manual BSONE-EVO v.2...
  • Page 56: Hydraulic Connection Diagram

    3.2- Hydraulic connection diagram 3.2.1- BSONE-EVO Series Equipment 1. From the swimming pool. 2. Filtration 3. Electrical Panel 4. Bypass 5. Flow Switch (optional) 6. Conductivity probe (optional) 7. Temperature probe (optional) 56 / 95 Manual BSONE-EVO v.2...
  • Page 57: 2- Auto Kit

    The following figures show the parts of the kit, plus an installation diagram. 3.2.2.1- Parts 1- BSONE-EVO Equipment 2- Suction Tube (flexible) 3- Injection Tube (rigid) 4- Suction filter (place vertically on the bottom of the acid container) 5- pH Probe 6- Probe Holder 57 / 95 Manual BSONE-EVO v.2...
  • Page 58 3- Connect one end of the suction tube (2) to the PH control inlet (11). 4- Connect the other end of the suction tube (2) to the suction filter (4). 58 / 95 Manual BSONE-EVO v.2...
  • Page 59: 3- Advanced Kit (Orp)

    This probe enables you to adjust the equipment in AUTOMATIC operating mode. 3.2.3.1- Parts 1-REDOX Probe 2-Probe-Holder 3-Flange 4-Reference liquid 465mV. 59 / 95 Manual BSONE-EVO v.2...
  • Page 60: 4- Pro/2 Kit (Free Chlorine) Optional In Bsone-Evo Equipment

    3.2.4.1 – Kit content 3.2.4.1.1- Probe Holder 3.2.4.1.2- Free Chlorine Probe Includes CC1 Probe Membrane (Included in the header) Protection cap ECC1.1/GEL Electrolyte Abrasive paper 60 / 95 Manual BSONE-EVO v.2...
  • Page 61 Header-membrane change: Once a year Maintenance period Electrolyte change: Every 3-6 months, depending on the quality of the water 3.2.4.3- Installation Please, carefully follow the recommendations regarding probe installation in order to ensure its proper operation: 61 / 95 Manual BSONE-EVO v.2...
  • Page 62 -As an alternative, the inlet can be connecter before the filter, but then it is strictly necessary to install a specific cartridge filter to avoid the probe contamination. 62 / 95 Manual BSONE-EVO v.2...
  • Page 63 Please, take care that this step is done correctly, otherwise the header membrane could be damaged, and will be out of warranty. 63 / 95 Manual BSONE-EVO v.2...
  • Page 64 Connect the white cable to the (+) input, it has a red or blue mark in the right side. Connect the dark cable to the (-) input. Once the connection is done, screw the cap and the cable gland. 64 / 95 Manual BSONE-EVO v.2...
  • Page 65 1) Install the probe on the probe holder. Use a tool to ensure the sensor is correctly tightened. 2) Switch the filtration pump on and adjust the water flow. The red flow indicator must be floating in the mid part of the indicator: 65 / 95 Manual BSONE-EVO v.2...
  • Page 66 DPD-1 testing is observed, perform a calibration as follows: a. DPD-1 test. Take a water sample from the small plastic tap placed at the bottom part of the probe holder. 66 / 95 Manual BSONE-EVO v.2...
  • Page 67 Please, carefully read the following maintenance instructions for your PRO/2 Kit. The maintenance periods are illustrative, they are depending on factors such as the quality of the water and the installation maintenance, especially with the filtration system. 67 / 95 Manual BSONE-EVO v.2...
  • Page 68 3.2.5- NTC/1 kit (OPTIONAL) for BSONE-EVO units The temperature probe kit enables you to take a reading of the water temperature. Once the probe has been connected, the temperature will be displayed in the main screen. 68 / 95 Manual BSONE-EVO v.2...
  • Page 69: 6- Conductivity Kit

    - Install a 1”1/4 flange (not supplied) according with the pipe diameter where it will be installed. 3.2.6.2.2 Wire connection Once the conductivity sensor is installed, should be connected to the electrolisys unit as follows: 69 / 95 Manual BSONE-EVO v.2...
  • Page 70 This sensor does not require any special maintenance. However, if an incorrect value is observed, an visual inspection of the measure head is recommended, in order to detect any strange body which could be interfering with the correct operation. 70 / 95 Manual BSONE-EVO v.2...
  • Page 71: Electrical Wiring Diagram

    14- (red) Conductivity (12v) * activate the FLOW SWITCH operation in the configuration menu ** to connect the free chlorine probe, read 3.2.5 chapter K1: PH Relay K4: Auxiliary relay LK2: Stop/Start (see 3.3.3.1) F1: Fuse 71 / 95 Manual BSONE-EVO v.2...
  • Page 72 In this way, when the filtration pump turns on, the “filter” input must be connected to 220V, and when the pump stops, “filter” input connector must be at 0V. 72 / 95 Manual BSONE-EVO v.2...
  • Page 73 Attention: Never exceed 12A when using the auxiliary relay. For higher currents, supplement the circuit with a contactor. Remember that the relay is potential free, and therefore the circuit should be supplied externally. 73 / 95 Manual BSONE-EVO v.2...
  • Page 74 3.3.2.3- Filtering control through the auxiliary relay The filtering pump can be controlled through the auxiliary relay, following this diagram: Please remember that the equipment should be configured in "start-stop" mode, as detailed on chapter 3.3.3.1 74 / 95 Manual BSONE-EVO v.2...
  • Page 75: Start-Up And Adjustments

    Program 2 Cover(Y) -> Switch N.A OFF Program Cover(Y) -> Switch N.C Timer,min Flow Switch (N)S Acid (Alkali) Clock menu pH Alarm (Y)N Chloride Alarm (Y)N Clock (time setting) 22h-9h Alarm Salt menu Calibration 75 / 95 Manual BSONE-EVO v.2...
  • Page 76 The fourth line displays the Menu (press the OK button to access the menu) and the time on the clock. If any alarm or warning occurs, it will also be displayed on this line. 76 / 95 Manual BSONE-EVO v.2...
  • Page 77 ATTENTION: A password will be required when trying to change some options of this menu, to avoid an involuntary change of some parameter that could affect to the right behavior of the unit. 77 / 95 Manual BSONE-EVO v.2...
  • Page 78 Select this mode if you do not have an ADVANCED (Redox) probe Kit, by adjusting production and hours of filtering depending on the nature of your swimming pool, its volume number of bathers and season of the year. 78 / 95 Manual BSONE-EVO v.2...
  • Page 79 The daily chlorination time will be calculated based on this parameter and the water temperature. Whenever the value is changed, on exiting the menu the screen will display the minimum filtering time the pump should work. 79 / 95 Manual BSONE-EVO v.2...
  • Page 80 This will indicate that the cover is activated. Once the cover detect ion is activated, the system will ask which is the type of sensor you have installed: Normally open (N.O.) or Normally Closed (N.C.) 80 / 95 Manual BSONE-EVO v.2...
  • Page 81 4.1.4.8 Acid / Alkali With this option you can select the type of pH corrector to be used in your swimming pool. Attention: It should be selected correctly otherwise the dosing system will work opposite to expected. 81 / 95 Manual BSONE-EVO v.2...
  • Page 82 Despite this alarm is been implemented to detect if a probe is not in good conditions, or there is some chemical issue in the water, it can be disabled if the user wants to maintain the production despite everything. Note: Password “1234” is required to modify this function. 82 / 95 Manual BSONE-EVO v.2...
  • Page 83 NOTE: if working in automatic, you can also adjust the production percentage from 0% to 100%, PPM Mode in which a free chlorine probe (OPTIONAL) is installed. 83 / 95 Manual BSONE-EVO v.2...
  • Page 84 With this menu, you can adjust the parameters related to the pH adjustment of your swimming pool. It only appears in BSONE-EVO series equipment. 4.1.6.1- Main screen The reading of the pH probe can be seen in the 3rd line of the main screen. 84 / 95 Manual BSONE-EVO v.2...
  • Page 85 The second line of the display indicates the measured value of pH. Wait until the reading stabilizes and then wait for at least one more minute. Press the "OK" button. 85 / 95 Manual BSONE-EVO v.2...
  • Page 86 Go to the "pH" menu and select "Manual". Keeping the "OK" button pressed, the pump will be running. Keep the pump running with the "OK" button until the liquid has passed throughout the tube until injection. 86 / 95 Manual BSONE-EVO v.2...
  • Page 87 See pages 23 and 24 of this manual for further details. 4.1.7.1- Start/Stop This manually turns the relay on / off. 4.1.7.2- Program (1/24h) This allows one single programming a day from 0h to 23.59. 87 / 95 Manual BSONE-EVO v.2...
  • Page 88: Warning Messages And Alarms

    4.2.1- Warnings Message: Causes: Action required: "LACK OF SALT" Lack of salt in the water. Add salt to the swimming pool. Incrustations or objects in Clean the cell. the electrolysis cell causing lack of current. 88 / 95 Manual BSONE-EVO v.2...
  • Page 89 (Water The value of the water Consider the use of a temperature) is flashing temperature under winter hibernator 15º. product. Filter time equipment Restart the filtering cycle switched off before the time semi- automatic 89 / 95 Manual BSONE-EVO v.2...
  • Page 90 It can work in manual mode if necessary. Water contains very low Leave the equipment to chlorate redox potential. in manual mode for at least 2 hours. Check the chemical balance of the water. (appendix 1) 90 / 95 Manual BSONE-EVO v.2...
  • Page 91: Operation Time

    5.1 section. Don’t allow to keep the cell working in these conditions for a long time. 5 - MAINTENANCE Carefully follow the recommendations and safety warnings detailed in section 1.4 of this manual. 91 / 95 Manual BSONE-EVO v.2...
  • Page 92: Cleaning The Electrolysis Cell

    Wait for the reading of the ORP value displayed on the screen to stabilize. Check that the value does not differ by more than about 10 mV of the value indicated on the label. If the value is incorrect, it can be attempted to 92 / 95 Manual BSONE-EVO v.2...
  • Page 93: Checking And Maintenance Of The Ph Probe

    To locate any possible problems, you can follow the recommendations in the following table: PROBLEMS CAUSE SOLUTION Reading = 0, does not coincide with the DPD- Failure in the connection of 1 measurement the sensor with the controller Check connections 93 / 95 Manual BSONE-EVO v.2...
  • Page 94 Repeat conditioning of the sensor and DPD-1 sufficient conditioning time recalibrate. Repeat the DPD-1 measurement with DP-! Reactives are worn new reactives Failure in the connection of Unstable reading the sensor with the controller Check connections 94 / 95 Manual BSONE-EVO v.2...
  • Page 95: Guarantee And Service

    Transport costs will be covered by the equipment owner. It is important to bear in mind that all repairs under guarantee are performed at the factory, or by an authorized BSV Electronic technical service. 95 / 95 Manual BSONE-EVO v.2...