Mounting On Din Rails - Siemens SIMATIC NET SCALANCE XB-200 Series Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

Installation

5.2 Mounting on DIN rails

5.2
Mounting on DIN rails
Installation clearances
Keep to the following minimum clearances so that the convection ventilation of the device is not
blocked:
● Below at least 10 cm
● Above at least 10 cm
Installation
Figure 5-1
To install the device on a 35 mm DIN rail complying with DIN EN 60715, follow the steps below:
1. Place the housing guide of the device on the top edge of the DIN rail
2. Press the device down against the DIN rail until the spring catch locks in place
3. Fit the connectors for the power supply, see the section "Power supply (Page 39)".
4. Insert the terminal blocks into the sockets on the device.
30
DIN rail mounting
Operating Instructions, 03/2020, C79000-G8976-C359-09
.
.
SCALANCE XB-200