Wiring Rules - Siemens SIMATIC NET SCALANCE XB-200 Series Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

Connecting up

6.3 Wiring rules

6.3
Wiring rules
When wiring use cables with the following AWG categories or cross sections.
Wiring rules for ...
connectable cable cross sec‐
tions for flexible cables ...
Stripped length of the cable
Wire end ferrule according to DIN 46228 without plastic ferrule**
* AWG: American Wire Gauge
** See note "Wire end ferrules"
Note
Wire end ferrules
Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp
cross sections.
Crimp shapes with wave-shaped profile are unsuitable.
38
without wire end ferrule
with wire end ferrule with plastic
ferrule**
with TWIN wire end ferrule without
plastic ferrule**
Operating Instructions, 03/2020, C79000-G8976-C359-09
Spring-loaded terminals
0.2 - 1.5 mm
2
AWG: 24 - 14
0.25 - 0.75 mm
2
AWG: 24 - 14
0.25 - 1.5 mm
2
AWG: 24 - 18
10 mm
10 mm
SCALANCE XB-200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents