FATEK FBs-W2C User Manual page 13

Wi-fi communication module
Table of Contents

Advertisement

FBs-W2C User Manual
To put the W2C into the Smart Config mode, needs to switch the W2C rapidly
3 times in succession.
After the W2C is powered on, it must be powered off within three seconds.
After repeating twice, the Smart Config mode will be enabled when the third
power is turned on.
After entering the SC mode, W2C starts waiting for Esptouch broadcast
information. At this time, the LED will flash continuously to indicate that the APP
can start transmitting, the longest waiting time is 60 seconds.
If the connection fails after 60 seconds (such as wrong information, unstable
network quality), W2C will enter the PLC application interface mode and
connect through information stored in PLC before.
Since the Smart Config connection method is subject to the hardware
compatibility, we provide Appendix C-Access Point Compatibility Table for users
to choose the appropriate mobile phone for connection settings.
Figure 8: Esptouch operation interface, display W2C IP when connect successfully