The pump supplied on these units is a
centrifugal type with a maximum flow of 450
L/min and maximum head of 75 m. It is mated
to a Honda GX160 petrol motor with a power
output of 5.5 HP.
Hydraulic Shock
If the water flow is suddenly terminated by
closing a valve without stopping the pump
first, it can cause hydraulic shock. This can
travel back to the pump causing serious
damage. To prevent pump damage turn valves
slowly.
Cavitation
Your pump is cavitating if knocking noises and
vibrations can be heard when it is operating. If
you continue to operate your pump when it is
cavitating, it will be damaged.
How to avoid cavitation
Minimise the number of valves and bends
in suction line
Suction length should be as short as
possible
Suction pipe should be at least the same
diameter as the pump inlet connection
Use long radius bends
Do not allow air into the suction line
Ensure adequate submergence, at least
5.3 times the suction hose diameter
Pump Performance
For maximum performance, efficiency
and life, operate the pump at the best
efficiency point which is 85% of total
pump head (75 m).
To maximize pump life, drain pump after
use and flush out with clean, fresh water.
Read engine manufacturer's owner's
manual thoroughly and service as
recommended.
Store pump in a dry, safe location when
not in use.
Aussie Quik Prime pumps are specifically
designed to pump water. Pumping other
liquids may shorten life and impact on
warranty.
Pumping water containing solids will
prematurely wear pump components, and
may impact warranty.
Ensure that the correct size strainer is
installed on the suction hose at all times,
even on trash pumps.
Aussie QP 5 year warranty
Australian Pump warranties all Aussie QP self
priming centrifugal pumps, whether used for
domestic or commercial applications, to be
free of faulty workmanship or material for a
period of 5 years from the date of supply to
the end user.
Aussie will replace or repair, at their discretion,
any faulty pump free of charge subject to the
following conditions:
Engine Warranty
Warranty for engines fitted to Aussie Pump
products is the responsibility of the engine
manufacturer or his representative and subject
to their terms and conditions, and operating
instructions included with the product.
The Aussie Pump 5 year warranty naturally
does not cover the following:
1. Normal wear and tear, misuse, improper
installation, negligent handling, failure to
follow operating instructions or to carry
out maintenance.
2. Pumping of chemicals, salt or corrosive
fluids.
3. Unauthorised repair or attempted repair
(i.e. not authorised by Australian Pump)
4. Shipping or transit damage
5. Use of non-genuine parts.
The warranty is valid only for the original
consumer purchaser and non transferable.
NOTE: This warranty is limited to the cost of
the product and does not include third party
costs including pump installers, plumbers etc.
Unless expressly authorised by Australian
Pump Industries in writing.
Contact your Goldacres Dealer to arrange a
warranty claim.