This Manual is NOT for use on SR3 Type 2 Modes 3, 8, 14 & 15 This document is the private unpublished property of Money Controls Ltd and may not be reproduced in part or in total by any means, electronic or otherwise, without the written permission of Money Controls Ltd. Money Controls Ltd does not accept liability for any errors or omissions contained within this document.
Table 7: Teach and Run™ Programming - Bank 2....................10 Table 8: DIL Switches - Decrease Security ......................15 Table 9: DIL Switches - Increase Security......................15 CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 2 of 19...
“Enable Bank 1 / Disable Bank 2” Removed Typo’s in Section 9. Issue 5.2………………………………………………………………………………..18 August 2003 Applied TMWP V3.2 Changed page header to include Modes 14 and 15. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 3 of 19...
Set Prices (Mode 7 only) Enable / Disable Banks Table 1: DIL Switch Functions Program 1 Program 2 Program 3 Program 4 Teach on/off Security on/off CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 4 of 19...
Teach and Run™ Window 3 Set Price 1 Set Price 2 Note: SR3 Type 2 modes 3 and 8 can not use any MechTool functions. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 5 of 19...
The inserted coin/s will now be accepted. Note:- It is possible for a single coin to be enabled using the above procedure even though that particular bank has been disabled. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 6 of 19...
The LED will turn GREEN. The selected coin/s will now be rejected. Table 3: Switch Position v Coin Window Coin No. SW1 MSB SW4 LSB CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 7 of 19...
Press the reject lever to return to normal operational mode. The LED will turn GREEN. The selected coin/s will now be accepted. Table 4: Switch Position v Coin Window Coin CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 8 of 19...
Even though a coin/token has been programmed make sure that the coin channel has actually been enabled (see section 3). Teach & Run™ does NOT automatically enable the taught coin/token. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 9 of 19...
BANK 2 Table 7: Teach and Run™ Programming - Bank 2 Coin Number Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 10 of 19...
Note: if a fault condition occurs (flashing RED), either power off, power on and restart teaching or press the reject lever, this will exit Teach and Run , the LED will change colour from flashing RED to GREEN. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 11 of 19...
Set ALL the DIL switches to the OFF position. Press the reject lever to return to operational mode. LED will change to constant GREEN. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 12 of 19...
If 2 counts were not enough and 3 counts were actually required, the procedure has to be repeated for +3 counts (NOT an extra +1 count). CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 13 of 19...
If 2 counts were not enough and 3 counts were actually required, the procedure has to be repeated for +3 counts (NOT an extra +1 count). CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 14 of 19...
Set the DIL switches to either Increase Security 0 or Decrease Security 0. This will set the sensor windows tweak value to 0 for the coin channel selected, i.e. the original programmed sensor windows. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 15 of 19...
Switch off the power to the SR3. Set ALL the DIL switches to the OFF position. Switch on the power to the SR3. The alarm is now OFF. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 16 of 19...
Price 2 has now been saved to EEPROM. Note:- To set Price 1 or Price 2 to 0 (Free Sales Mode), don’t enter any coins. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 17 of 19...
Switch off the power to the SR3. Set ALL the DIL switches to the OFF position. Switch on the power to the SR3. The changes are now stored in Eeprom. CONFIDENTIAL Not to be disclosed without prior written permission from Money Controls Page 18 of 19...