Camera installation

6

Installation location

■ Monitor installation location
Standard monitor installation height
is about 1,500mm where screen
center is at eye level.
In this case, wall-hanging metal
center (center of piping) is 1,450mm
above ground level.
Standard installation height
■ Caution of camera installation
Avoid installing camera exposed to direct ray of light (and sun).
Beware backlight and darkness of visitor's face, which makes identification difficult.
Avoid installing camera in places such as the following picture.
(1) Place illuminating sky as background
(2) Place with white wall reflecting direct ray of light
(3) Place with direct ray of light
■Monitor installation
■ Directly connecting cut-off power cord with power wire
1) Do not do such electric work on your own. Installing product in this way
requires reliance on electric installation man with electric work license.
2) Insulate with insulating tape while cutting off power cord and connecting with power
wire so electric wire metal does not expose. Contact between exposed electric wires
cause fire or electric shock accident.
3) Such electric work requires connection after interception of supplied power.
1) Remove wall-hanger bracket metal behind monitor.
2) Install wall-hanger bracket metal on 1 type box or wall with attached Vis.
3) Connect wiring to monitor back terminal referring to product connection diagram.
4) Hang monitor on wall-hanging metal, and fix monitor on wall- hanger bracket metal
using attached Vis.
5) Plug monitor's power plug into consent and check to see if the power switch is [ON]
on the left side of monitor.

Product connection diagram

■Name of each connection port
Program
write
Extention Monitor
GND
VOICE 1
VOICE 2
VIDEO INPUT
DATA
PABX
DATA-PABX
VIDEO OUT
■ Camera installation location
Camera installation in height Standard
camera installation height is when
lens is about 1,400mm above the floor.
In this case, camera stack center
(piping box) is above 1,390mm above
ground level.
Standard installation in height
※The above angel of view is based on the KC-MC24 camera.
The numbers very according to the type of camera.
DC Type
Power cord
ADAPTOR
7