Pressure gauges with switch function
Type series BE, BR, BF, BG, BN, BP
Operating Instructions
1 General Information....................................................................................................... 2
1.1 Intended Use ........................................................................................................... 2
1.2 General Safety Notes .............................................................................................. 2
1.3 Conformity with EU Regulations .............................................................................. 2
1.4 ATEX Approval ........................................................................................................ 2
2 Transportation and Storage .......................................................................................... 2
3 Installation and Commissioning .................................................................................. 2
3.1 Mechanical Installation ............................................................................................ 3
3.2 Electrical Connection .............................................................................................. 3
3.3 Adjusting of contacts ............................................................................................... 4
3.4 Additional requirements relating to type BN4xxx pressure switches and type
BP4xxx pressure limiters ......................................................................................... 4
4 Operation ........................................................................................................................ 5
4.1 Zero-point correction ............................................................................................... 5
4.2 Maintenance / Service ............................................................................................. 5
5 Disassembly ................................................................................................................... 5
LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany
Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: sales@labom.com www.labom.com
BA_037_2019-05_10.00
Page 1/5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Labom BE Series

  • Page 1 4.1 Zero-point correction ....................5 4.2 Maintenance / Service ..................... 5 5 Disassembly ........................5 LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany BA_037_2019-05_10.00 Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: sales@labom.com www.labom.com Page 1/5...
  • Page 2 In addition to this instruction, be sure to observe all statutory requirements, appli- cable standards, the additional technical specifications on the accompanying data sheet (see www.labom.com) as well as the specifications indicated on the type plate. Intended Use The device is intended to measure pressure of gases, vapors and liquids as specified in the data sheet.
  • Page 3 Mechanical Installation Use gaskets, if required, that are suitable for the process connection and resistant to the media. Before starting operation, check the process connection carefully for leaks under pressure. Install safety pressure gauges in the line with DIN EN 837-1 S1 and S3 so that the exhaust equipment can freely discharge to the rear in the event of a fault or malfunction.
  • Page 4 Operating the contact outside of the scale range is not permitted. You can find additional information on contacts in the document TA_039, available on our website at www.labom.com. Additional requirements relating to type BN4xxx pressure switches and type BP4xxx pressure limiters The evaluation unit and downstream control current circuit are not part of our scope of supply.The following evaluation units conform to the requirements of the Association of...
  • Page 5 Operation During operation, take care that the device remains within its intended pressure and tem- perature ranges. No other monitoring is necessary. The permissible ambient and media temperature depends on the type of device and its design. This information can be found in the relevant data sheet. Restricted ambient conditions may apply in explosion protected environments (see XA_013, XA_014 or XA_021).

This manual is also suitable for:

Br seriesBf seriesBg seriesBn seriesBp series

Table of Contents