Cut Hazard; Rated Indoor Airflow (Cfm) - Carrier WeatherExpert 48LC 07 Series Installation Instructions Manual

Single package rooftop unit gas heat/electric cooling with puron (r-410a) refrigerant
Hide thumbs Also See for WeatherExpert 48LC 07 Series:
Table of Contents

Advertisement

CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care
and wear appropriate protective clothing, safety glasses and
gloves when handling parts and servicing air conditioning
equipment.
Position:
Example:
Unit Heat Type
48 - Gas Heat Packaged Rooftop
Model Series - WeatherExpert
LC - Ultra High Efficiency
Heat Options
D = Low Gas Heat
E = Medium Gas Heat
F = High Gas Heat
S = Low Heat w/ Stainless Steel Exchanger
R = Medium Heat w/ Stainless Steel Exchanger
T = High Heat w/ Stainless Steel Exchanger
Refrig. Systems Options
0 = Three stage cooling capacity control with TXV
A = Three stage cooling capacity control with TXV
®
and Humidi-MiZer
System
Cooling Tons
07 - 6 ton
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
F = RA Smoke Detector and CO
G = SA Smoke Detector and CO
H = RA + SA Smoke Detector and CO
Indoor Fan Options
1 = Standard Static Belt Drive with VFD controller
2 = Medium Static Belt Drive with VFD controller
3 = High Static Belt Drive with VFD controller
Coil Options: Fin/Tube (Condenser- Evaporator - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu -Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
1
2
3
4
5
6
7
8
4
8
L
C
D
0
0
7
®
2
2
2
Fig. 1 — Model Number Nomenclature

Rated Indoor Airflow (cfm)

Table 1 lists the rated indoor airflow used for the AHRI effi-
ciency rating for the units covered in this document. See Fig. 1
for unit options, Fig. 2 for unit dimensions, and Fig. 3 for ser-
vice clearances.
Table 1 — Rated Indoor Airflow (cfm)
MODEL NUMBER
48LC**07
9 10 11 12 13 14 15 16 17 18
A
1
A
5
-
0
A
0
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels and
5 = Hinged Panels and
Intake / Exhaust Options
A = None
B = Low Leak Temperature Economizer
with Barometric Relief
E = Low Leak Enthalpy Economizer
with Barometric Relief
N = Ultra Low Leak Temperature Economizer
with Barometric Relief
R = Ultra Low Leak Enthalpy Economizer
with Barometric Relief
Base Unit Controls
0 = Electro-mechanical Controls
1 = RTU Open Multi-Protocol Controller
4 = SystemVu™ Controller
Design Revision
- = Factory Design Revision
Voltage
1 = 575/3/60
5 = 208-230/3/60
6 = 460/3/60
3
FULL LOAD AIRFLOW (CFM)
2250
A
0
Packaging
0 = Standard
1 = LTL
Electrical Options
A = None
B = HACR Circuit Breaker
C = Non-Fused Disconnect
D = Thru-The-Base Connections
E = HACR Circuit Breaker
and Thru-The Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
Unpowered Convenience Outlet
Powered Convenience Outlet