Wiring Equipment And Options - Watt Drive L2000 Series Manual

Table of Contents

Advertisement

Wiring equipment and options

CAUTION
Provide the wiring equipment in accordance with the safety codes required
by jurisdictional authorities. If specified in standards or laws and regulations,
follow their istructions. In the following table some guidelines for choosing an
appropriate wire gauge are presented:
Motor
output
(kW)
0.2
L2000-002NFE
0.4
L2000-004NFE
0.55
L2000-005NFE
0.75
L2000-007NFE
1.1
L2000-011NFE
1.5
L2000-015NFE
2.2
L2000-022NFE
0.4
L2000-004HFE
0.75
L2000-007HFE
1.5
L2000-015HFE
2.2
L2000-022HFE
3.0
L2000-030HFE
4.0
L2000-040HFE
5.5
L2000-055HFE
7.5
L2000-075HFE
Cable specifications
Inverter
model
Power lines
1.5 mm
(AWG 15)
2.5 mm
(AWG 13)
4.0 mm
(AWG 11)
4.0 mm
(AWG 11)
1.5 mm
(AWG 15)
1.5 mm
(AWG 15)
2.5 mm
(AWG 13)
1.5 mm
(AWG 15)
2.5 mm
(AWG 13)
2.5 mm
(AWG 13)
4.0 mm
(AWG 11)
1.5 mm
(AWG 15)
2.5 mm
(AWG 13)
2.5 mm
(AWG 13)
4.0 mm
(AWG 11)
2.5 mm
(AWG 13)
4.0 mm
(AWG 11)
4.0 mm
(AWG 11)
2.5 mm
(AWG 13)
4.0 mm
(AWG 11)
4.0 mm
(AWG 11)
4.0 mm
(AWG 11)
4.0 mm
(AWG 11)
Page 26 / 52
600V fuse to be
Signal
(rated current / A)
lines
2
2
2
25 A (single phase)
16 A (three phase)
2
40 A (single phase)
25 A (three phase)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Wiring
used
10 A
16 A
10 A
10 A
16 A
10 A
16 A
16 A
25 A
10 A
16 A
16 A
25 A
16 A
25 A
25 A
16 A
25 A
25 A
25 A
25 A