To reduce wear on the collection
bag, do not drag it along the
ground while working.
If the device stops suddenly during
operation and does not produce
any suction, then it is to be switched
off immediately. Pull out the power
plug and make sure that no material
is wedged in between the shredder
impeller and the casing. Carry out
the work as described in the chap-
ter "Cleaning and Maintenance". If
the appliance will not start, consult
our Service Centre.
Emptying the collection bag:
With full collection bag, the suction pump-
ing capacity decreases considerably and
the collection bag must be emptied when
the bag is full or interferes with the suction
capacity of the device.
Disconnect the device and pull out
the power plug before emptying the
collection bag. Danger of electric
shock!
1. Wait until the impeller wheel comes to
a standstill.
2. To remove the collection bag, remove
the retainer loop (
coupler lever on the frame (
3. Open the zip-fastener on the collection
bag and empty it completely.
4. Mount the emptied collection bag
again (see also "Assembly Instruc-
tions").
Composting material does not be-
long with domestic waste!
19) and press the
B
17).
B
Cleaning and mainte-
nance
Pull out the power plug before all
work on the device.
Leave all work not described
in this manual to our Service
Centre. Only use original
parts.
Before every use, check the device for obvi-
ous deficiencies, such as loose, worn or
damaged parts and for correct seating of
the parts. Replace damaged parts. Check
the bag regularly for wear and tear.
Carry out the following maintenance and
cleaning work regularly. By this means, a
long and reliable life is guaranteed.

General cleaning

Clean the device in each case im-
mediately after working, since other-
wise mud with leaf residues hardens
and sets and can possibly no longer
be removed without dismantling the
motor casing.
Such cleaning work is not covered
by the guarantee.
Do not employ any cleaning agents
or solvents. They can irreparably
damage the device. Chemical sub-
stances can attack the plastic parts
of the device.
Clean the device casing, the tube and
the ventilation slots regularly with a soft
brush or a cloth. Never clean the de-
vice under running water.
Take off the collection bag after finishing
work, turn it inside out and brush it thor-
oughly. In this way, you avoid the gen-
GB