12.19 Hook the stainless steel housing into the hook-in strip and fasten with screws.
12.20 Connect the connecting hose with the water volume regulator to the mixed-water
line or the cold-water line.
12.21 Open the water volume regulator with a hollow hexagon wrench.
d: closed
e: open
12.22 Check the water connections for leaks.

13. Function

Triggering water flow
13.1 Press the Piezo-button.
• Water flows.
• Water flow stops automatically after the set flow duration time has passed or
when the Piezo-button is pushed again.
Flow duration
The flow duration has been factory-set to 30 s. The flow duration can be altered in
steps of 0.1 seconds, from 1 – 6500 s.

14. Adjusting the Flow Duration

Flow duration can be adjusted with a free program available from Franke.

15. Setting Hygiene Flushing

Hygiene flushing can be adjusted with a free program available from Franke.

16. Maintenance and Servicing

Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the fitting must be maintained and serviced at regular
intervals.
Perform maintenance on the following components:
• Shower head (see
• Filters (see
Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
Chapter
17.)
Chapter
18.)
- 9 -