Important Notes; Application - Franke AQUATIMER A3000 Installation And Operating Instructions Manual

Shower panel made of stainless steel, 24 vdc
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
4.

Important Notes

• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
• When using the device for paid water distribution with AQUAPAY coin-activated
switches, carefully observe the connection guide provided in the instructions for
the AQUAPAY coin-operated switch.
• All rights reserved to make technical alterations.
5.

Application

AQUATIMER - A3000 open shower panel made of stainless steel, for on-wall instal-
lation, with electronic time-control and a facility for paid water distribution via
AQUAPAY coin-activated switch, and a feature for externally controlling options such
as fitting settings and communication via ECC function controller. For connecting to
pre-mixed warm or cold water supply. Split-second adjustment of flow duration.
Control functions:
– Optional temperature sensor on the hot water side; the temperature is
measured and a protocol is saved every 60 seconds, during thermal disin-
fection every 10 seconds
– Time-controlled hygiene flushing, optionally with fixed interval or after a certain
defined time after last usage
– Peak load program for demand-oriented fitting functions
Additional functions with ECC function controller (Ethernet):
– Automatic thermal disinfection according to DVGW work sheet W 551 as well
as safety switch-off
– Cleaning switch-off