MODEL 1205B/C & 1206B/C SETUP GUIDE
Unpacking
Carefully check the packing material for these accessories: GNSS antenna, standard antenna cable
assembly, and mounting screws for rack ear removal. Handle the GNSS antenna carefully, as it may
be damaged if dropped.
Installing GNSS Antenna
The GNSS antenna included with the clock is designed to be threaded onto a piece of 3/4 in pipe nipple.
Make sure that the antenna has a clear view of the sky in all directions of the compass for best GNSS
satellite tracking.
1. Pass the antenna cable through the pipe nipple and attach the cable to the antenna. Tighten by
hand, spinning the cable connector. DO NOT spin the antenna onto the cable or DAMAGE may
occur.
2. Thread the pipe nipple into the base of the antenna and snug by hand.
3. Mount the pipe nipple to a fixture, such as our Antenna Mounting Kit.
4. Install GNSS Surge Protector or In-Line Preamplifier if needed. Reference their respective instruc-
tions.
5. Connect the antenna cable to the clock.
Connecting Power Cables
• VERIFY that the voltage level is in the correct range.
• VERIFY that the polarity is as specified on the label.
• Strip the insulation 1/4 inch and DO NOT tin.
• A fuse is located to the left of each installed power inlet connector.
Connecting Signal Cables
Strip the insulation 1/4 inch and DO NOT tin.
Arbiter Systems, Inc. 1324 Vendels Circle, Suite 121 Paso Robles, CA 93446 USA Tel: +1.805.237.3831
Fax: +1.805.238.5717 E-mail: techsupport@arbiter.com Internet: http://www.arbiter.com
GNSS Antenna
3/4 inch Pipe Nipple
Operate LED
Figure 1: Antenna Mounting Assembly
Antenna Cable
Mounting Point
PD0053000C
1

Advertisement

loading

Summary of Contents for Arbiter Systems 1205B

  • Page 1 • A fuse is located to the left of each installed power inlet connector. Connecting Signal Cables Strip the insulation 1/4 inch and DO NOT tin. Arbiter Systems, Inc. 1324 Vendels Circle, Suite 121 Paso Robles, CA 93446 USA Tel: +1.805.237.3831 Fax: +1.805.238.5717 E-mail: techsupport@arbiter.com Internet: http://www.arbiter.com PD0053000C...
  • Page 2 3. The default username is admin and the default password is password. Additional Help The operation manual is available as a free download from www.arbiter.com or to purchase. Arbiter Systems, Inc. 1324 Vendels Circle, Suite 121 Paso Robles, CA 93446 USA Tel: +1.805.237.3831 Fax: +1.805.238.5717 E-mail: techsupport@arbiter.com Internet: http://www.arbiter.com...