initialization failure
Gate A20 failure
General failure
Hard disk controller failure
Hard disk read failure
Invalid configuration information - please
run SETUP program.
Invalid memory configuration detected.
Potential for data corruption exists!
Invalid NVRAM configuration, resource re-
allocated
I/O card parity interrupt at address
Keyboard controller failure
Keyboard data line failure
Keyboard stuck key failure
Keyboard clock line failure
Keyboard failure
Memory allocation error
Memory address line failure at address, read
value expecting value
Memory high data line failure at start
address to end address
Memory high address line failure at start
address to end address
Memory double word logic failure at start
address to end address
Memory double word logic failure at address,
read value expecting value
Memory odd/even logic failure at start
address to end address
Memory odd/even logic failure at address,
read value expecting value
Memory write/read failure at address, read
value expecting value
Memory write/read failure at start address to
end address
Memory parity failure at start address to end
address
Memory parity error at address
No boot device available
No boot sector on hard- disk
No timer tick interrupt
No PXE-capable device available
Non-system disk or disk error
Not a boot diskette
Faulty keyboard controller (defective
system board).
Application program or operating system
failure.
Incorrect configuration settings in the
System Setup program, improperly
connected hard drive, or faulty hard-
drive controller subsystem (defective
system board).
Incorrect configuration settings in the
System Setup program, the NVRAM_CLR
jumper is installed, or the system
battery is faulty.
Memory modules are not installed in
matched pairs.
System configuration data has been
ignored.
Expansion card(s) is improperly installed
or faulty.
Defective keyboard/mouse controller
(defective system board).
Keyboard cable connector is loose or
improperly connected; defective
keyboard; defective keyboard/mouse
controller (defective system board).
Memory module(s) is not connected
properly, or an application program or
the operating system failed.
Faulty or improperly seated memory
modules or defective system board.
Improperly seated or faulty memory
modules.
Faulty diskette, diskette/CD drive
subsystem, hard drive, or hard-drive
subsystem; no boot disk in drive A.
No operating system on the hard drive.
Defective system board.
<F12> was pressed during POST and no
PXE devices are detected.
Faulty diskette, diskette drive
subsystem, or hard-drive subsystem.
No operating system on diskette.
RAC. If the problem persists, you may need to replace the
system board. See
"Getting
Help."
Replace the system board. See
"Getting
Reboot. If the message reappears, see your software
documentation.
Check the hard-drive configuration settings in the System
Setup program. See "Using the System Setup Program" in the
User's Guide. Reinstall the hard drive. See
Hard
Drives" in "Installing Drives."
Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide. Remove the
NVRAM_CLR jumper. See
Figure A-2
Replace the battery. See
"Replacing the System
"Installing System Options."
Install memory modules in matched pairs. See
Memory
Modules" in "Installing System Options."
Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide.
Reinstall the expansion card(s). See
Cards" in "Installing System Options." If the problem persists,
replace the expansion card(s).
Replace the system board. See
"Getting
Check the keyboard cable connection. Replace the keyboard.
If the problem persists, replace the system board. See
"Getting
Help."
Reseat the modules. See
"Installing Memory
"Installing System Options." Reboot the system. If the
message reappears, see your software documentation.
Remove and reseat the memory modules. See
Memory
Modules" in "Installing System Options." If the
problem persists, replace the memory modules. If the problem
persists, see
"Getting
Help."
Remove and reseat the memory modules. See
Memory
Modules" in "Installing System Options." If the
problem persists, replace the memory modules. If the problem
persists, see
"Getting
Help."
Replace the diskette or the hard drive. See
If the problem persists, replace the system board. See
"Getting
Help."
Check the hard-drive configuration settings in the System
Setup program. See "Using the System Setup Program" in the
User's Guide.
Replace the system board. See
"Getting
Check the cables connected to the NICs. Check the
configuration settings in the System Setup program for the
NICs. See "Using the System Setup Program" in the User's
Guide.
Replace the diskette. Reseat all drives and reboot the
system. If the error message reappears, see
Use a bootable diskette.
Help."
"Installing SCSI
for jumper location.
Battery" in
"Installing
"Installing Expansion
Help."
Modules" in
"Installing
"Installing
"Installing
Drives."
Help."
"Getting
Help."