Installation Of Outdoor Unit - LG ATUQ22GPLA4 Installation Manual

Hide thumbs Also See for ATUQ22GPLA4:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION OF OUTDOOR UNIT

Installation Places
- If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that
heat radiation from the condenser is not restricted.
- Ensure that the spaces indicated by arrows around front, back and side of the unit.
- Do not place animals and plants in the path of the warm air.
- Take the air conditioner weight into account and select a place where noise and vibration are
minimum.
- Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
Piping length and the elevation
Ceiling Suspended Air conditioner
MODEL
Gas
Ø 12.7 (1/2) Ø 6.35 (1/4)
ATUQ22GPLA4
Ø 12.7 (1/2) Ø 6.35 (1/4)
ABUQ22GM1A4
ATUQ30GPLA4
Ø 15.88(5/8) Ø 9.52(3/8)
Ø 15.88(5/8) Ø 9.52(3/8)
ABUQ30GM1A4
AUUQ40GH4
Ø 15.88(5/8) Ø 9.52(3/8)
AUUQ50GH4
Ø 15.88(5/8) Ø 9.52(3/8)
Ø 19.05(3/4) Ø 9.52(3/8)
AUUQ60GH4
*Columbia standard pipe uses 5m.
More than
300 mm
F e
n c e
o b
o r
s t a
c l e
s
More than 700 mm
Pipe Size
Length A (m)
Standard
Liquid
7.5
7.5
7.5
7.5
7.5
7.5
7.5
INSTALLATION OF OUTDOOR UNIT
Unit : mm
More than
More than
300 mm
300mm
More than 600 mm
Elevation B (m)
Max.
Standard
Max.
30
5
15
30
5
15
50
5
30
50
5
30
50
5
30
50
5
30
5
30
50
7
Additional
Refrigerant (g/m)
20
20
40
40
40
40
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents