Download Print this page

Applicable Standards - Panasonic KC2S Eco-COUNT METER Manual

Power-on counter, power-on hour meter

Advertisement

2. Dedicated CT
Item
Diameter of conductor to be measured
Breakdown voltage (Initial value)
Insulation resistance (Initial value)
Allowable number of detachments/attachments
Vibration resistance (Functional)
Vibration resistance (Destructive)
Shock resistance (Functional)
Shock resistance (Destructive)
Operating temperature range
Storage temperature
Mass (Weight)
Ambient humidity
Note: For Eco-COUNT METER and Eco-HOUR METER, this CT is supplied together.

APPLICABLE STANDARDS

(EMI) EN61000-6-4
Radiated emission electric field strength
Noise terminal voltage
(EMS) EN61000-6-2
EMC
Static discharge immunity
RF electromagnetic field immunity
EFT/B immunity
Conductivity noise immunity
Power frequency electric field immunity
PART NAME
Eco-HOUR METER
h
RESET
KE2S
Front reset key
(Terminal block side)
Lock switch
(Mark on the unit
)
1
Notes: 1. ∗ Factory setting.
2. Make the switch setting before installing to panel.
3. Common to Eco-COUNT METER and Eco-HOUR METER.
DIMENSIONS
(Common to Eco-COUNT METER
and Eco-HOUR METER)
1. Main unit
1) One touch installation type
10.4
(44)
.409
(1.732)
22
.866
7
.276
2) Installation frame type
10.4
(44)
.409
(1.732)
22
.866
7
.276
10 dia. (max.)
1,000 Vrms AC for 1min: Between core and output connector terminal
Min. 100MΩ: Between core and output terminal (at 500V DC)
Approx. 100 times
10 to 55 Hz: 1 cycle/ min single amplitude of 0.15 mm
10 to 55 Hz: 1 cycle/ min single amplitude of 0.375 mm
Min. 98 m
321.522
ft./s
Min. 294 m
964.567
–10°C to +50°C
+14°F to 122°F
–20°C to +60°C
–4°F to 140°F
Approx. 55g
1.94oz
35 to 80% R.H. (at 20°C non-condensing)
Lock switch
OFF∗
(LCD side)
ON
44.8
1.764
54.4
2.142
48
5
1.890
.197
Eco-COUNT METER
24
.945
KC2S
44.8
1.764
54.4
2.142
48
5
1.890
.197
Eco-COUNT METER
24
.945
KC2S
Front reset key
Specification
.006 inch
.015 inch
2
(4 times on 3 axes)
ft./s
2
(5 times on 3 axes)
(Without frost or dew)
(Without frost or dew)
(trunk cable included)
EN55011 Group 1 Class A
EN55011 Group 1 Class A
EN61000-4-2
4 kV contact
EN61000-4-3
10 V/m AM (80 MHz to 1 GHz)
EN61000-4-4
1 kV (Signal line)
EN61000-4-6
10 V/m AM (0.15 MHz to 80 MHz)
EN61000-4-8
30 A/m (50Hz)
1. Main unit
1) Front reset key
This key resets the count value of Eco-COUNT METER and elapsed
time of Eco-HOUR METER.
It does not work when the lock switch is ON.
Note that frequent operation may shorten battery life.
2) Lock switch (Refer to chart on left)
Ineffective the front reset key
Note: LCD side is ON (reset ineffective); terminal block side is OFF (reset effective)
2. Dedicated CT
2. Dedicated CT
3. Trunk Cable
1000
39.37
Note: The trunk cable connects the main unit and dedicated CT.
It is included with the main unit.
26/03/2013
KC2S(AKC2)/KE2S(AKE2)
(10 min on 3 axes)
(1 h on 3 axes)
General tolerance: ±1.0
mm
inch
26
1.024
1
23
1
.039
.906
.039
13.5
0
0
10
dia.
.394
dia.
.531
–0.5
–.020
39
1.535
27
1.063
±5
150
±.197
5.906
±50
±1.969
±.039

Advertisement

loading

This manual is also suitable for:

Ke2s eco-hour meterAkc2421Akc2621Ake2421Ake2621Akc2 ... Show all