Download Print this page

Emerson InSinkErator Grind2Energy Service Manual page 22

Organics recycling system

Advertisement

MODEL
ENGINEERING #
CERTIFIED
GC-1
14176
UL & CUL
GC-2
14176A
International
2
3
4
1
CODE
DESCRIPTION
1
Non-Metallic Enclosure
2
Door Disconnect Kit
3
Pushbutton STOP (N.C. Red)
4
Pushbutton START (N.O. Black)
5
Pushbutton FLUSH (N.O. Yellow)
6
Remote Sensor Light (FULL)
7
Pushbutton De-Jam (REV)
8
24V Fuse
9
120V Fuse
10
Terminal Block - 3 Phase
11
Transformer - 3 Phase
12
Circuit Board, Printed
13
Relay 3-Pole
InSinkErator Division
844-874-7529
Emerson Electric Co.
grind2energy.com
4700 21st Street
Racine, WI 53406-5093 USA
G2E015-15F-89-84
ELECTRICAL
208-230 Volt / 10 HP / 3 Ph
415 Volt / 5 HP / 3 Ph
24
8
9
5
6
QTY
PART
NUMBER
1
N/A
1
14728
1
14158
1
14159
1
14470
1
N/A
1
14370
X
XXXXX
X
XXXXX
18
14805
1
14185
1
14788
1
14812
15
16
17
13
12
11
14
10
21
20
DC
ok
L1
L2
DC ok
2 2 2 4 4 4 7 10 11 12 15 M1 M2 M3 T1 T2 T3
1 ON
Adjust
Power Supply
L1
L2
INPUT
N
N
DC
ok
L1
L2
L3
2 2 2 4 4 4 7 10 11 12 15 M1 M2 M3 T1 T2 T3
DC ok
1 ON
Adjust
Power Supply
L1
L2
L3
INPUT
N
N
CODE
DESCRIPTION
14
Contactor - Aux Pump
15
Mechanical Interlock
16
Reversing Contactor - 3 Phase
17
Relay 3-Pole
18
Overload 208-230V
18
Overload 380-460V
19
Ground Lug
20
DC Supply For Pressure
21
Pressure Relay
22
Disposer Delay Time Relay
23
Timed off Relay
24
Forward Contactor
Solenoid Valve - 24 Volt Coil (Not Shown)
The Emerson logo is a trademark and a service mark of Emerson Electric Co.
InSinkErator may make improvements and/or changes in the specifications
at any time, in its sole discretion, without notice or obligation and further
©2015 InSinkErator, a business unit of Emerson Electric Co. All Rights Reserved.
PARTS LIST
GC-1 / GC-2
22
23
DC
ok
TANK
FLUSH
START
STOP
DC ok
L1
L2
L3
2 2 2 4 4 4 7 10 11 12 15 M1 M2 M3 T1 T2 T3
1 ON
Adjust
Power Supply
L1
L2
L3
INPUT
N
N
ELECTRICAL SHOCK HAZARD. DISCONNECT INCOMING POWER
WARNING
BEFORE SERVICING CONTROL CENTER. FAILURE TO DO SO COULD
RESULT IN DEATH OR SERIOUS PERSONAL INJURY. DOOR
INTERLOCK SWITCHED DISCONNECT CONTROL CIRCUIT ONLY.
18
7
19
L3
L3
PRESS IF
JAMMED
2
TANK
FLUSH
START
STOP
WARNING
ELECTRICAL SHOCK HAZARD. DISCONNECT INCOMING POWER
BEFORE SERVICING CONTROL CENTER. FAILURE TO DO SO COULD
RESULT IN DEATH OR SERIOUS PERSONAL INJURY. DOOR
INTERLOCK SWITCHED DISCONNECT CONTROL CIRCUIT ONLY.
QTY
PART
NUMBER
1
1
1
1
1
1
X
XXXXX
X
XXXXX
X
XXXXX
X
XXXXX
X
XXXXX
X
XXXXX
2
reserves the right to change or discontinue models.
PRESS IF
JAMMED
TANK
FL
WARNIN
14813
14169
14160
14813
14792
14793
14494

Advertisement

loading

This manual is also suitable for:

Gd-1Gc-1Gc-2