Save/Load Profile Command

The Save/Load Profile command allows you to save and load connection
profiles. Saving profiles will save the connections currently in use.
The formula for the Save/Load Profile command is as follows:
Command + Profile + Number + Control + [Enter]
For example, to save the current connection configuration to profile 02, type:
profile f 02 save [Enter]
The following tables show the possible values for the Save/Load Profile
commands:
Command
Profile Number
Control
Note: Each command string can be separated with a space.
The following table lists the available Save/Load Profile commands:
Command Profile
profile
f
profile
f
profile
Save / Load profile
Profile
f
Profile command
yy
01~08 (default is 01)
save
Save the connection configuration
load
Load a saved profile
Profile
Control Enter
Number
save
yy
*
load
yy
*
Chapter 5. CLI Commands
Description
Description
Description
Description
Description
[Enter] Save the connections as profile yy.
(yy:01~08 or 01~17, *)
[Enter] Load profile yy.
(yy:01~08 or 01~17, *)