Removal Of Upper Case; Removal Of A-P.c.board - Panasonic PT-D5600U Service Manual

Hide thumbs Also See for PT-D5600U:
Table of Contents

Advertisement

PT-D5600U / PT-D5600E / PT-D5600UL / PT-D5600EL / PT-DW5000U / PT-DW5000E / PT-DW5000UL / PT-DW5000EL

11.2. Removal of Upper Case

(1)
Unscrew the 8 screws and remove the top plate.
(2)
Remove the filters (R, L). (Pull them horizontally out.)
(3)
Unscrew the 1 screw and remove the lamp unit cover while
sliding it horizontally.
(4)
Unscrew the 8 screws and remove the upper case.
Note:
· Confirm the lens lock button actuates correctly when
you reassemble the upper case as it was.
· When you attach the upper case, take care not caught
nor protruding of the dustproof sheet around the
projection lens.
· After attaching the upper case, remove and reinstall the
projection lens according to the section 11.11.
"Removal of Projection Lens" because the dustproof
sheet might protrude or deform.

11.3. Removal of A-P.C.Board

(1)
Remove the upper case according to the section 11.2. "Removal
of Upper Case".
(2)
Unscrew the 6 screws and remove the terminal cover.