Download Print this page

Festo NEBU-M8R3 Series Assembly Instructions page 2

Connecting cable

Advertisement

Available languages

Available languages

Assembly instructions (Translation: en)
758564 / 2011-07NH
Connecting cable
NEBU-M8R3-...
The connecting cable is intended to be used as an M8 round plug connector
for low voltage applications.
1. Technical data
NEBU-M8R3-...
Cable diameter
Tightening torque
Acceptable current load at 40 °C
Operating voltage range AC/DC
†‡
Festo AG & Co. KG
Postfach
D-73726 Esslingen
++49/(0)711/347-0
www.festo.com
D
[mm]
4.5
M
[Nm]
0.2 ... 0.3
A
[A]
0.5
U
[V]
0 ... 60
B
2. Assembly
1
A
16301d_3
16301d_2
1
16301d_4
2
16301d_5
Information
After the nut 2 is tightened, a motion range of ± 15° remains possible.
Since the socket 1 is rotatable
(360°), the orientation of the
2
pins in the socket 2 cannot be
determined based on the cable
outlet.
• Place the socket 2 onto the
2
plug (A). Pay attention to the
correct orientation of the
pins in the socket 2.
• Turn the socket 1 in 15°
steps to the desired position.
• Tighten the nut 2. Observe
the permitted tightening
torque M
.
A

Advertisement

loading

This manual is also suitable for: