en Installation instructions
▶ Only use genuine spare parts when repair-
ing the appliance.
▶ If the power cord of this appliance is dam-
aged, it must be replaced by trained spe-
cialist staff.
Improper installation is dangerous.
▶ Connect and operate the appliance only in
accordance with the specifications on the
rating plate.
▶ Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.
▶ The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.
▶ Never equip the appliance with an external
switching device, e.g. a timer or remote
control.
▶ When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.
▶ When installing the appliance, check that
the connection cable is not trapped or
damaged.
15.4 Instructions for the electrical
connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug for the mains power cable must be
easily accessible after the appliance is installed.
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
¡ "The connection data can be found on the rating
plate." → Page 13
¡ The connecting cable is approx. 1.30 m long.
16
¡ This appliance complies with the EC interference
suppression regulations.
¡ The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡ Do not connect the appliance to the power supply
during installation.
¡ Ensure that the protection against contact is guaran-
teed during installation.
15.5 Information on the installation situation
¡ Install this appliance in a worktop.
¡ The appliance is not suitable for combined opera-
tion with a gas hob.
¡ To install additional special accessory parts, ob-
serve the enclosed installation instructions.
To ensure that the appliance does not lose any power,
do not install any wall units above the appliance and
maintain the following clearances:
¡ At least 50 cm to the left and right from the appli-
ance to a wall or to an adjacent wall unit
¡ At least 5 cm from the frame of the appliance to a
wall
¡ At least 2 cm from the Guided Air suction area to a
unit wall
15.6 Instructions for the exhaust air pipe
The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.
¡ Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.
¡ Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.
¡ Use an exhaust pipe that is made of non-combust-
ible material.
¡ To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.
Note: Suitable air extraction ducts are available from
our after-sales service, your dealer or on our website.
Flat ducts
Use flat ducts with an inner cross-section that corres-
ponds to the diameter of the round pipes:
¡ Diameter of 150 mm corresponds to ap-
prox. 177 cm².
¡ Diameter of 120 mm corresponds to ap-
prox. 113 cm².
¡ Use sealing strips for different pipe diameters.
¡ Do not use any flat ducts with sharp bends.
Round pipes
Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.
15.7 General information
Follow these general instructions during the installation.
¡ For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.
¡ When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.