Performing A Robotic Self-Test - Primera DP-4202 XRP User Manual

Table of Contents

Advertisement

Continue to hold the Cartridge Button for five seconds. After sever-
al more seconds, the robotics will undock and the arm will lower.
Power will shut off automatically once the robotics are in transport
position. If you have the cardboard spacer that was shipped with
the unit, replace the spacer inside the unit and close the cover. If you
don't have the cardboard spacer, secure the arm and cartridges to
the sides of the unit with tape and close the cover.
D. PERFORMING A ROBOTIC SELF-TEST
To ensure that everything is working properly, a Self-Test feature is
built in to your Publisher. In this mode, the Robotic Disc Transporter
will go through the motions of picking and placing a disc to ensure
proper working order. This test may be performed without connect-
ing the Publisher to the PC.
Perform the test by doing the following steps:
Load some discs into the Input Bin
Open the TOP DRIVE by pressing the eject button on the drive.
The cover must be closed for this operation to complete.
However, in order to access the buttons you must open the cover. To
get around this problem simulate closing the cover by activating the
cover lock sensor. You may do this by putting an object such as a
folded piece of paper in the slot where the lock would normally be
located.
With the Publisher turned on, press
the Cartridge Button
While holding the Cartridge Button, press the Power
Button until the robotics start to move.
Release both buttons
To stop the test, wait until the disc has moved to the Output Bin
and press the Power Button.
Maintenance and Troubleshooting
41

Advertisement

Table of Contents
loading

Table of Contents