Accessories; Precautions For Selecting A Location - Daikin RXL18UMVJU Installation Manual

Room air conditioner
Hide thumbs Also See for RXL18UMVJU:
Table of Contents

Advertisement

Accessories

A
Installation manual
C
Drain cap (1)
E
Warranty

Precautions for Selecting a Location

1) Choose a place solid enough to bear the weight and vibration of the unit, where the operating sound will not be amplified.
2) Choose a location where the air discharged from the unit or the operating sound will not cause a nuisance to the neighbors of
the user.
3) Avoid locations, such as near bedrooms, where the operating sound may cause disturbance.
4) There must be sufficient space to carry the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must not be prone to flammable gas leaks in the surrounding area.
7) In coastal areas or other places with a salty atmosphere or one containing sulfate gas, corrosion may shorten the life of the air
conditioner.
8) Since water will flow from the drain of the outdoor unit, do not place under the unit anything which must be kept away from
moisture.
NOTE
Cannot be installed suspended from a ceiling or stacked.
CAUTION
When operating the air conditioner in a low outdoor ambient temperature, be sure to
follow the instructions described below.
• To prevent exposure to wind, install the outdoor unit with its suction side facing the
wall.
• Never install the outdoor unit at a site where the suction side may be exposed
directly to wind.
• To prevent exposure to wind, it is recommended to install a baffle plate on the air
discharge side of the outdoor unit.
• In heavy snow areas, select an installation site where the snow will not affect the unit.
• If there is a likelihood of snow accumulating on the outdoor unit, attach a snow
protection hood.
• In high humidity areas or heavy snow areas, it is recommended to attach a drain pan
heater to prevent ice build-up from the bottom frame.
3
B
Drain socket
1
This is at the bottom of the packaging.
D
Drain cap (2)
6
1
1
3
• Construct a large canopy.
• Construct a pedestal.
Install the unit high enough off
the ground to prevent burying
in snow.