Bailey platinum standard PTSP Series Product Instruction page 21

Smart pressure transmitter
Table of Contents

Advertisement

INTRODUCTION
Item
Type STT Smart Transmit-
ter Terminal
1
EZ CAL option
Liquid crystal display
1
option
1
Analog meter option
1
Process adapter option
(straight)
Process adapter (football
style)
1
Mounting bracket option
1
Degreasing option
Gold plated Hastelloy
1
C-276 diaphragm option
Tantalum diaphragm
Remote diaphragm seals
1
Lightning arrestor option
Antistatic kit
Available drawings
B8113038
D3055062
D3055064
D3055065
OPTIONS AND ACCESSORIES
1 - 12
Table 1-7. Options and Accessories
Hand-held device for calibration, configuration, monitoring, and troubleshooting.
Also communicates with HART devices.
External nonintrusive device for zero and span validation. Add on
kit no. 258562_1.
Two-line, seven-character display for local output indication. Displays output in
percent and user-defined secondary engineering units, input in primary engi-
neering units, cell temperature, and transmitter ID tag. Mounts in four orienta-
tions for easy viewing. Refer to Table
kit no. 258550_1 (aluminum cover) or 258550_5 (stainless steel cover).
Provides local output indication for those applications where the transmitter
operates outside the temperature limits of the LCD. Linear 0 to 100 and square
root 0 to 10 graduations on same scale. Add on kit no. 258550_2 (aluminum
cover) or 258550_6 (stainless steel cover).
½ NPT male to female stainless steel 316 or Hastelloy C-276.
Part no. 1951753_ _.
½ NPT stainless steel 316 for connection to flanged manifold.
Part no. 1948994_1.
Universal support for mounting on panel or 1.5 in. to 2.0-in. pipe. Available in
Zinc-plated, chromate-dipped carbon steel, or stainless steel 316.
For use in oxygen or chlorine service.
For use in hydrogen service.
For use with highly corrosive fluids.
For use with high temperature and corrosive fluids or where impulse line
clogging may be a problem.
Mounts internally to suppress lightning induced transients. Tested to suppress
10 successive 8 by 20 µsec pulses with a peak value of 20 kA (reference
IEEE C62.41).
Contains static-dissipative work surface (mat), ground cord assembly, wrist
bands, and alligator clip for personnel working on devices containing semicon-
ductor components. Kit no. 1948385_1.
Board level wiring diagram.
Dimension drawing for Type PTSP pressure transmitters.
Dimension drawing for optional indicator.
User field connections.
Description
1-3
for the temperature limitations. Add on