Bailey platinum standard PTSP Series Product Instruction page 17

Smart pressure transmitter
Table of Contents

Advertisement

INTRODUCTION
Property
Temperature limits for
electronics, cell, and
Parameter
optional liquid crystal
display
Normal
operating
Extreme
operating
Storage/
transport
Supply voltage
12 to 53 VDC (12 to 42 VDC for CSA certified applications)
Power supply effect
Analog mode
±0.005% of URL per volt
Digital field bus mode ±0.003% of URL per volt
Output signal
Analog
4 to 20 mA
Digital
Bailey FSK communications
Output current limiting
≥21.6 mA
Maximum
≤3.7 mA
Minimum
Loop load limits
Refer to Figure
Damping/response
Analog and digital response to a step input change is adjustable from 0.0 to
time (one time con-
32.0 secs and is entered during configuration. This value is in addition to:
stant - approximately
Cell response time: dependent on cell and fill fluid
62% of final reading)
Electronics response time: approximately 0.3 sec
≤±0.1% of URL in fields from 4 to 1,000 MHz at 10 V/m
RFI/EMI effects
Surge tolerance
Complies to IEEE 472 test criteria. 2.5 kV, 1.5 MHz at 10 V/m
Vibration effect
±0.1% of URL for 1 g from 1 to 2,000 Hz in any axis of the transmitter
Enclosure rating
NEMA 4X and IP67
FM/CSA
6,7
certifications
Explosionproof and
Class I, Division 1, Groups B, C and D; Class II, Division 1, Groups E, F and G;
dust-ignitionproof
Class III
Intrinsically safe
Classes I, II and III, Division 1; applicable groups when connected per drawing
B222611
Nonincendive
Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups E, F and G;
Class III
NOTES:
1. The normal operating temperature range is that at which the transmitter meets all specifications. The extreme operating temperature
range is that at which the transmitter remains powered without damage.
2. All transmitters with fluorinated oil filled cells can only be operated in temperatures from -10° to +80°C (+14° to +176°F).
3. The normal operating temperature range for the LCD is that at which the LCD remains functional. Exceeding those conditions may cause
the LCD to go blank. The transmitter remains functional to its operating limits. When the temperature returns to the acceptable range, the
display is restored; however, the life of the display may be reduced.
4. The minimum supply voltage necessary to support communications is 17.0 VDC.
5. Add 0.4 VDC to all minimum supply voltage values if using the lightning arrestor option.
6. Refer to Table
1-4
for the ambient condition limits for certified applications.
7. The transmitters are only certified for those agencies and classes indicated on the certification label. Do not install the transmitters in
locations for which they are not suited. Refer to nomenclature position 12.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
SPECIFICATIONS
1 - 8
Table 1-3. Common Specifications
Characteristic/Value
1
Electronics
°C
°F
-40 to +85 -40 to +185
-50 to +85 -58 to +185 -50 to +120 -58 to +248
-55 to +85 -67 to +185
2-4
(continued)
1,2
Cell
°C
°F
°C
-40 to +85
-40 to +185
0 to +50
0 to +50
-55 to +85
-67 to +185 -20 to +70
4,5
. Installation category III.
3
LCD
°F
+32 to +122
+32 to +122
-4 to +158
WBPEEUI110506A0

Hide quick links:

Advertisement

Table of Contents
loading