Worcester GREENSTAR 24i junior Instruction Manual page 44

Wall hung rsf gas-fired condensing combination boiler installation, commissioning & service
Table of Contents

Advertisement

43
REPLACEMENT OF PARTS
11
C
C
9
A
10
B
Spare Fuse order
T1.6L 250V F2
T2.5H 250V F1
T500L 250V F3
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior
REPLACEMENT OF PARTS
9. Access to boiler control components
Remove 3 screws (A) and remove cover
from control.
10. PCB fuse
Remove fuse F1(B) from the PCB and
replace.
There is a spare fuse clipped into the
underside of the electrical cover.
11.Transformer / PCB
Disconnect all electrical connections from
the control.
Remove 5 screws (C) retaining the rear
panel of the control and remove panel.
8 716 107 336b (11/05)