Advertisement

Mounting and installation manual
Garage door opener GTZ-Digital

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GTZ-Digital Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for tousek GTZ-Digital Series

  • Page 1 Mounting and installation manual Garage door opener GTZ-Digital...
  • Page 2: Table Of Contents

    Installation declaration ..........................39 This manual is the sole property of the TOUSEK Ges.m.b.H. and may not be made available to competitors. All rights reserved. No part of it may be reproduced without our prior written permission. We will not accept liability for any claims resulting from misprints or errors. This edition of the manual replaces all earlier publications of the same.
  • Page 3: Explanation Of Symbols

    ATTENTION - FOR PERSONAL SAFETY, IT IS VITAL TO FOLLOW ALL INSTRUCTIONS. PLEASE KEEP THIS MANUAL READILY ACCESSIBLE. IMPORTANT INSTRUCTIONS FOR A SAFE INSTALLATION: ATTENTION - IMPROPER INSTALLATION CAN RESULT IN SERIOUS INJURY. PLEASE FOLLOW ALL MOUNTING INSTRUCTIONS. - 3 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 4: About This Document

    • Excluded from the warranty are batteries, fuses and bulbs. Additional safety information available in the relevant sections of the document. „4. Installation“ „5. Commissioning“ „6. Operation“ „7. Maintenance“ „8. Dismantling“ - 4 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 5: General Features, Application, Technical Details

    • photocells LS 55/3 • safety edge module • flashlight module • LED extension ATTENTION: This operatorcan be installed indoors only! Under no circumstances it should be exposed to rain or moisture, like in an open carports! - 5 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 6: Scope Of Delivery

    The product is supplied in different versions.Use the chart and the scope of delivery to check which version you have. Country-specific variations are possible. Pos. Motor Pos. Connecting elements- 01 Pos. Fittings Pos. Connecting elements - 02 Pos. Warning labels - 6 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 7: Door System

    For garages without a second entrance: • Equip the garage door with an emergency release, in order to beeing able to enter the garage also in case of a malfunction. - 7 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 8: Mounting

    If you are not using a releasing kit: • Remove the locking mechanisms or put them out of operation. When using and installing accessories, please observe the relevant documentation. 4.2 Mounting Mounting Ø 5–5,5 Ø 5–5,5 - 8 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 9 10 - 50 mm below the horizontal bottom edge of the drive rail. • Mount the lintel joining plate for the operator track centered over the door leaf. Ø 10 - 9 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 10 OPEN position Install the limit stop for the OPEN position as shown above! • The position of the limit stop on the rail defines how far the gate opens. - 10 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 11: Control Connections

    „4.3.2 Connection on terminal K“ Connection MS-BUS for extension modules: - safety edges module (optional) preinstalled „Level 8, Menu 2 - safety sensing edge  Connection radio receiver RS 868-GTZ „4.3.3 connection receiver“ - 11 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 12: Connection At Terminal Strip K

    • Make sure that after the installation no door parts are spread are not connected. onto public footpaths or roads. • However, once detected the devices must remain connected. • Only by carrying out a RESET you can reset the functions. - 12 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 13: Putting Into Operation

    (Example: Menu 3, Parameter 8) minute + 20 seconds = 80 secunds 5.2 Status display Putting into operation Status display Function / element Indicator for warning time (only by pro- grammed automatic closing) - 13 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 14: Quick Programming

    The remote control code is therefore stored. If additional transmitter have to be stored, so the whole z.B. process must be repeated. Full description of of the radio „11. Radio- programming“ . - 14 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 15: Factory Settings

    • The door-frame photocell must work above the installed position. Under the installation point is the function suppressed by the control unit. • If several photocells are connected, all the photocells work in the same way as the door-frame photocell. - 15 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 16: Special Programming

    Display the first menu and the programmed parameter. P > 5 sec.:Finish program- ming. All the adjusted para- meters are saved. Select the required menu The control unit is in (e.g. menu 3). operating mode. - 16 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 17: Overview On Special Functions

    Reset central unit Reset safety devices (photocells / hold circuit) No Function Reset Bus Module Reset extension automatic mode (connected bus modules will be deleted) „level 3, - automatic mode“ - 17 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 18 Door stationary: lighting Door movement / warning: lighting Door movement / warning: flashing Door stationary: OFF (energy saving) Door stationary: lighting Door movement / warning: flashing Door movement / warning: lighting Door stationary: blinking Door stationary: flashing Level 4 no function - 18 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 19 = 1 (do not change) Level 5 Factory settings = 1 - do not change! Menu 7 Optional function = 1 (do not change) Level 5 Factory settings = 1 - do not change! - 19 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 20 Soft start time 6 seconds Level 6 Menu 10 Soft start time CLOSE Soft start time 1 second Soft start time 3 seconds Soft start time 2 seconds Soft start time 6 seconds - 20 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 21 Menu 9 Error display Display of the current error message (max. 16 error messages possible). Display the previous errors / Browse through the error list Browse through the error list - 21 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 22 – long Menu 8 rotation direction Level 8 Standard reversed rotation direction Level 8 Menu 0 special functions door-frame photocell DO NOT ADJUST ATTENTION: DO NOT ADJUST! - 22 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 23: Operation

    Control unit is in operating 2. Impulse: mode. the system stops. 3. Impulse: 1 impulse: the door runs in The door opens and runs in the opposite direction direction OPEN. CLOSE. - 23 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 24: Release

    Danger of damage to property due to uncontrolled movement of the door! When opening the door manually, the carriage could collide with the carriage stop. • When the mechanism is released, only move the door carefully and at a moderate speed! - 24 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 25: Maintenance, Care And Cleaning

    • Dispose of old batteries in a battery recycling container or via a specialist dealer. • Dispose of the packaging material in the special waste collection containers for paper, cardboard and plastic. - 25 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 26: Troubleshooting

    • Check error message (LC dysplay). • Hold article code, production no. and revision status (see nameplate ) ready Any other problems. for queries. • Reset and commissioning in accordance with EBA. - 26 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 27: Faults With Fault Messages

    • Check the door movement und Tor gangbar movement. machen. • Check the door positions OPEN and CLOSE / Wrong setting for door position CLOSE. reset them. • Check the door. - 27 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 28: Radio Programming

    Explanation of symbols for radio programming Signal tones of the receiver press the button and release the button process completed keep it pressed continuous tone slow tone sequence fast tone sequence - 28 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 29: Saving A New Transmitter

    Once the channel within P3: memorizing has been included into the receiver memory, you will hear 5 seconds ! button several consecutive beeps. - 29 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 30: Troubleshooting And Technical Data Radio Rs 868

    Impedance antenna input 50 Ω Modulation Operating temperature -20°C to +60 °C Electricity supply 3V (Lithium cell CR2032) Relay output pot. free Average power consumption 15 mA Operating temperature -10°C to +55°C - 30 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 31 - 31 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 32: Photocell Ls 55/3 (Optional)

    / receiver with the clamp 71 on the terminal strip K. Note the cable marks! common LS 55/3 cable 1: black/white marked photocell LS 55/3 cable 2: not marked photocell LS 55/3 transmitter receiver - 32 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 33 • The photocell is correctly adjusted if the green LED of the transmitter lighting constantly. transmitter receiver (green LED) (red LED) - 33 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 34: Flashlight Module (Optional)

    • If a switch or button will be connected (with identical function as the radio receiver) so its connection cable must be led through the rubber grommer (T) as well and connected to the clamps 1/2. button flashlight max. 230V, 60W - 34 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 35 Door stationary: OFF (energy saving) Door stationary: lighting Door movement / warning: lighting Door movement / warning: flashing Door stationary: OFF (energy saving) Door stationary: lighting Door movement / warning: flashing Door movement / warning: lighting Door stationary: blinking Door stationary: flashing - 35 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 36: Safety Edge Module (Optional)

    • Set the requested function of the safety sensing edge in the Door movement CLOSE: door reverses a long distance menu 5.6.3./ Level 8 / Menu 2, „safety sensing edge“.  final edge - 36 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 37 Motor number (Type plate): machine has to be inserted, complies with the the Machine Directive 2006/42/EC. Other components: Eduard Tousek, CEO Vienna, January 2015 - 37 - tousek / EN_GTZ-Digital_07 / 10. 10. 2019...
  • Page 38: Dimensional Drawing

    Buitenheide 2A/ 1 Tel. +32/ 11/ 91 61 60 your service partner: Fax +32/ 11/ 96 87 05 info@tousek.nl Tousek Sp. z o.o. Poland PL 43-190 Mikołów (k/Katowic) Gliwicka 67 Tel. +48/ 32/ 738 53 65 Fax +48/ 32/ 738 53 66 info@tousek.pl...

This manual is also suitable for:

Gtz-55 digitalGtz-110 digital

Table of Contents