Removing The Ki03 Belt - Bosch WTA4410US Repair Instruction

Table of Contents

Advertisement

6.10

Removing the Ki03 belt

Protective gloves must be worn
1.
Remove the worktop.
2.
Remove the rear panel.
3.
Pull off the electrical connections F for the heater and
temperature controller.
4.
Remove the bottom process air duct cover.
5.
Remove the process air impeller.
6.
Detach the belt over the drum.
7.
Remove the two top screws A on the process air duct.
8.
Thread the belt between the process air duct and housing.
9.
Insert and tighten the two screws A you removed earlier.
10.
Remove the two bottom screws B on the process air duct.
11.
Press the duct back and thread the belt between the housing
and process air duct
12.
Remove the belt.
Stretch belt before assembly!
113_58300000104082_ara_en_h.doc – 19.03.07
(see step
8).
Step 3
Seite 20 von 30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents