Care And Cleaning; Troubleshooting Guide - Braun CareStyle Compact Series Manual

Table of Contents

Advertisement

d. Close the tank lid, plug in and press the reset
button (14) for 5 seconds until the LED turns
off.
NOTE: After the replacement of the anti-limescale
filter cartridge press the steam button (2) for about
60 seconds and hold the iron horizontally to pull the
steam through to the soleplate.
In case of using demineralised water, you need to
leave the filter cartridge in the compartment and
press the reset button (14) for 5 seconds each time
the anti-limescale indicator turns permanently on
until the LED turns off.
We recommend using the CareStyle anti-limescale
filter cartridge (can be purchased in stores, through
www.braunhousehold.com or by calling Customer
Service).
Do not use any chemicals, additives or descaler to
rinse the water tank.

Troubleshooting guide

PROBLEM
The appliance does not
produce any steam.
The anti-limescale indicator is
on and less or no steam comes
out of the iron when pressing
the steam button.
8
CAUSE
There is not enough water in the
water tank.
The steam button has not been
pressed.
A new anti-limescale filter
cartridge has just been installed.
The anti-limescale filter cartridge
is not placed properly.
The anti-limescale filter cartridge
needs to be replaced.
(G) Care and cleaning
• Before cleaning, always make sure that the
appliance is unplugged and has cooled down
completely.
• To clean the soleplate it is suggested to use a
damp cloth.
• Never use chemicals, vinegar or scouring pads
(eg. sponges with coarse nylon fabrics etc).
Please do not dispose of the product in the
household waste at the end of its useful life.
Disposal can take place at a Braun Service
Centre or at appropriate collection points
provided in your country.
REMEDY
Unplug the appliance; check if the
anti-limescale filter cartridge has
been well prepared and is placed
properly; fill water up to max. level;
close the lid of the water tank; plug
in and wait until the temperature
control LED is permanently on;
press the steam button until steam
comes out of the soleplate.
In case above procedure does
not solve the problem take the
following steps: press RESET +
steam buttons together until steam
comes out. Once steam comes out,
release the buttons.
Replace the anti-limescale filter
cartridge and press the reset button
for 5 seconds until the LED turns
off.
You can also use demineralised wa-
ter. In that case, you need to leave
the anti-limescale filter cartridge
in the compartment and press the
reset button for 5 seconds each
time the the antilimescale indicator
turns on.