Installation Instructions

Wiring Diagram DNP Models 1500 and 2000 watts
Wiring Diagram DNP Models 1000 and 500 watts
1. Insert the supply cable through the strain relief
of the installation cover. Remove 1.97 inches
(50mm) of the outer insulation, and .4 inches
(10mm) of the inner insulation.
2. Connect the grounding wire to the chassis using
the designated grounding screw.
4
10mm
(.4 in.)
50mm
(1.97 in.)
3. Cut two 30mm pieces of the insulating sleeve
and slide over the black and white conductors of
the supply cable. Connect the black and white
leads to the corresponding wires on the heater,
using the wire nuts provided.
! NOTE: The insulating sleeve, supplied with the
product, must be placed over the exposed black
and white conductors of the supply cable.
4. Insert the two tabs of the installation cover into
the two slots in the chassis and fold the cover
over the wiring.
5. Fasten the installation cover with the two
screws. Make sure the supply cable is securely
fastened by firmly pulling it.
Pull