Installation Instructions
Connect the black from the power supply to the
black wire from the unit, connect the white wire from
the power supply to the white wire from the unit, and
connect the grounding wire to the chassis using the
designated grounding screw.
ELECTRICAL INSTALLATION
CAUTION: Disconnect electric power supply before
working on circuit wiring to prevent electric shock.
CAUTION: Electrical connection must have ground
fault protection (GFCI or GFI).
CAUTION: This heater must be grounded.
CAUTION: A circuit breaker is required for proper
installation, do not load beyond 80% capacity.
CAUTION: High temperature, risk of fire, keep
electrical cords, drapery, furnishings, and other
combustibles at least 3 feet (0.9 m) from the front of
the heater and away from the side and rear.
The heater is designed for indoor use as a room
heater and should not be used for any other
purpose. Any other use not recommended by the
manufacturer may cause fire, electric shock, or
injury to persons.
Before commencing installation, make sure that the
electrical supply voltage is the same as that shown
on the rating label of the heater.
To reduce the risk of fire, do not store or use
gasoline or other flammable vapors and liquids in
the vicinity of the heater.
Ensure that the heater has been securely fastened
in its final position.
The heater can only be installed horizontally. Do not
install the heater vertically. Failure to do this may
cause a fire risk or poor heater performance.
There are no user-serviceable parts inside the
heater. Any servicing other than regular cleaning of
the heater should be performed by an authorized
service professional.
WARNING: This heater must not be connected
to the electricity supply via an external switching
device (such as a timer) or a circuit that is regularly
switched on and off by the utility supplier. Failure
to follow this warning could result in the heater's
thermal cut-off being inadvertently reset and could
create a fire hazard.
IMPORTANT: The heater should be positioned
observing the minimum clearances stated around
the heater.
Minmum Clearances
Min.
30mm
(1.2 in.)
Wiring Diagram DEP Models 1500 and 2000 watts
Thermal Cutout
Heating Element
Thermal Cutout
Integrated Thermostat
Wiring Diagram DEP Models 1000 and 500 watts
Min.
300mm
(11.8 in.)
Min.
Min.
50mm
(1.97 in.)
30mm
(1.2 in.)
Min.
50mm
(1.97 in.)
Electronic Controller
Ground
L1
L2

Advertisement

loading

This manual is also suitable for:

Dnp seriesDep0500Dnp0500Dep1000Dnp1000Dep1500 ... Show all