NK TECHNOLOGIES AS3 Series Instructions

NK TECHNOLOGIES AS3 Series Instructions

Ac current operated switch w/jumper selectable range, ac or dc output

Advertisement

Quick Links

Specifi cations
None - self powered
Power Required
Setpoint Ranges
Fixed Core: 1-6, 6-40 & 40-175 A
Split Core: 1.75-6, 6-40, & 40-200A
Setpoint Adjust
4 Turn potentiometer, or 15 Turn (Suffi x
-FT)
Hysteresis
5% of setpoint
Isolation Voltage
UL Listed to 1,270 VAC
Frequency Range
6-100Hz
Output Switch
Isolated Solid State Switch
AC Switch Rating
1.0A@240VAC,
-03 Model
3A@120VAC, -FT housing only
-15 Model
10A @ 240 VAC, 15A @ 120 VAC when
mounted on 1ft
2
Max. 3A in free air.
Off State Leakage
All models: 2.4 mA
DC Switch Rating
0.15 Amp @ 30 VDC
Off State Leakage
NODC: None, NCDC: 1.35mA
Response Time
2.5 sec. max
Housing
UL 94-V0 Flammability Rated
Terminal Torque
5-7 inch-pounds
Environmental
-20 to 50 °C (-4 to +122° F)
(surrounding sensor)
0-95% RH, non-condensing
Pollution Degree 2
Overvoltage Category II
Altitude to 2000 meters
Current Measurement 0-200A @300V, CAT III
Approvals
UL and cUL Listed, CE
Caution! Risk of danger
Safe operation can only be guaranteed if the
transducer is used for the purpose for which it was
designed and within the limits of the technical speci-
fi cations When this symbol is used, it means you
should consult all documentation to understand the
nature of potential hazards and the action required to
avoid them.
Caution! Risk of electrical shock
When operating the transducer certain parts may
carry hazardous live voltage (e.g. Primary conductor,
power supply). The transducer should not be put into
operation if the installation is not complete.
Ranges & Maximum Amps
RANGE
RANGE
RANGE
SPLIT- CORE
JUMPER
SOLID CORE
NONE
1 - 6 A
1.75 - 6 A
MID
6 - 40 A
6 - 40 A
40 -200 A
HIGH
40 -175 A
Model Number Key
AS3 - NODC - FF - NL
, 930cm
2
metal surface.
OUTPUT (Solid State):
NCAC - Normally Closed, 1.0A, 240VAC
NOAC - Normally Open, 1.0A, 240VAC
NCDC - Normally Closed, 0.15A, 30 VDC
NODC - Normally Open, 0.15A, 30VDC
AADC* - Dual Normally Open, 0.15A, 30VDC
CCDC* - 1 N.O, 1 N.C., 0.15A, 30 VDC
SENSOR TYPE:
AS3 - AC current operated switch with 3 jumper select-
able ranges, adjustable setpoint and LED as standard
Know Your Power
Other NK Technologies Products Include:
AC & DC Current Transducers and Current Operated Relays
AC Ground Fault Sensors
1φ & 3φ kW Transducers
Current & Potential Transformers (CTs&PTs)
MAX
MAX
6 SEC.
1 SEC.
3511 Charter Park Drive, San Jose, CA 95136
Phone: 800-959-4014 or 408-871-7510
400 A
600 A
Fax: 408-871-7515 FAX
500 A
800 A
sales@nktechnologies.com, www.nktechnologies.com
800 A
1200 A
OPTIONS:
Blank - Standard with LED
NL - No LED
03 - 3A@120 VAC (-FT only)
15 - 15A@120 VAC/10A@240VAC
output. (-FF only)
CASE STYLE:
FF - Fixed Core, Front Terminals
FT - Fixed Core, Top Terminals
SP - Split-Core
*
each contact trip point adjustable between the range setting
-FF housing only
INSTRUCTIONS
AS3 SERIES
AC Current Operated Switch w/Jumper
Selectable Range, AC or DC Output
Quick "How To" Guide
1. Run the wire you are monitoring through ap-
erture.
2. Mount the sensor to a surface if needed.
3. Connect output wiring.
A. Use up to 14 AWG copper wires.
B. Make sure the load matches the output
shown on the sensors' label (volts, amps,
AC/DC).
4. Adjust Setpoint
A. Chose correct range by positioning the
Range Jumper
B. Use the potentiometer to adjust the set-
point.
5. Confi rm Contact Operation
A. If the sensor has an LED, quick fl ash indi
cates current over the set point and output has
tripped, slow fl ash shows current under set point,
output is shelf state condition.
AS3-AC-DC-Inst. P/N 391000201 Rev 4. 04/2016

Advertisement

loading

Summary of Contents for NK TECHNOLOGIES AS3 Series

  • Page 1 fi cations When this symbol is used, it means you should consult all documentation to understand the AC/DC). nature of potential hazards and the action required to Other NK Technologies Products Include: avoid them. 4. Adjust Setpoint AC & DC Current Transducers and Current Operated Relays Caution! Risk of electrical shock A.