Correct Alignment Procedure (Manual Restart) - SAFEasy SF2 Series Instruction Manual

Table of Contents

Advertisement

Instruction Manual

5.2. Correct alignment procedure (MANUAL RESTART)

OPERATING STATUS
SAFE
condition
Yellow
OFF
Yellow
OFF
Red
OFF
Green
ON
- Normal
operating
mode, no
beams are
interrupted
When the mechanical installation and the electrical connections have
been effected – as explained in the previous paragraphs – it is
possible to carry-out the alignment of the safety light curtain, according
to the following procedure:
• Check the green LED ON the bottom of the TX unit (POWER ON)
and the yellow LED (SAFE); if they are ON, the unit is running
correctly.
• Check that no opaque objects are inside the controlled area.
• Verify that one of the following conditions is present on the RX unit:
WAITING FOR RESTART CONDITION (BREAK)
1. The green LED (SAFE) is OFF and the red LED (BREAK) is ON.
The yellow LED (HIGH ALIGN) is ON, the yellow LED (LOW
ALIGN) is OFF. Light curtain aligned and restart available. Press
TEST push-button for to change to Normal Condition (SAFE).
25
SF2 Series
WAITING
for
BREAK
RESTART
condition
condition
(BREAK)
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
- Light
- Non-
- Non-
-
Light
curtain
aligned
aligned
curtain
aligned,
light
low side
aligned but
- Restart
curtain,
- Lowest
at least
availabile
- Non-
beam
one beam
aligned
interrupted
is
high side
interrupted
- Highest
(except
beam
the highest
interrupted
and lowest
beams)

Advertisement