wiring
Receptacle wiring should be a minimum of
14 gauge. Use copper wire only. It is the
responsibility
of the consumer to provide
proper and adequate receptacle wiring,
installed by a qualified electrician. Observe
National Electrical Code and all local
governing codes and ordinances.
Electrical
connection
Electrical ground is required on this air
conditioner.
Recommended
grounding
method
For your personal safety, this air conditioner
must be grounded. This air conditioner is
equipped with a power supply cord
having a 3-prong grounding plug. To mini-
mize possible shock hazard, the cord
must be plugged into a mating 3-prong
grounding-type
wall receptacle, grounded
in accordance with the National Electrical
Code (ANSVNFPA 70 - latest edition) and
local codes and ordinances. If a mating wall
receptacle is not available, it is the responsi-
bility of the customer to have a properly
grounded 3-prong wall receptacle installed
by a qualified electrician.
Electrical
requirements
A 115 volt (103.5 min., 126.5 max.), 60 Hz,
AC only, 15 ampere fused electrical supply
is required (time delay fuse or time delay
circuit breaker required). It is required that a
separate circuit, serving only this air condi-
tioner, be provided.
3-prong
grounding
Plug
3-prong
grounding
type wall
Poker
SUPPlY
cord
L receptacle
(single outlet)