M24E & M36E ELECTRICALLY OPERATED BOILERS PARTS AND SERVICE MANUAL EFFECTIVE SEPTEMBER 2, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are not available. ERRORS: Descriptive and/or typographic errors are subject to correction.
High limit switch set too low or operating pres- Follow instructions in this document for read- down and fails to come on sure control switch set too high justing, or replace if defective SEPTEMBER 2, 2014 M24E & M36E ELECTRIC BOILERS...
Page 4
Wrong coil Check rating (voltage and frequency) if incor- rect, replace with proper coil Shorted turns caused Replace coil Under voltage, failure of magnet to seal in Correct system voltage. Install new coil SEPTEMBER 2, 2014 M24E & M36E ELECTRIC BOILERS...
1. Remove screw and lift front cover off control box. 2. Hand adjust operating pressure control switch and high limit pressure control switch by turning adjust- ing nut (Knurled knob) clockwise to raise and coun- SEPTEMBER 2, 2014 M24E & M36E ELECTRIC BOILERS...
Use V-O-M to verify that there is power at the • DO NOT remove wires from L 1 & L2 terminals. ‘FW(NO)’ terminal. • Tag wires and remove from probe and relay contact terminals including ‘GND’ terminal. SEPTEMBER 2, 2014 M24E & M36E ELECTRIC BOILERS...
Page 7
Use V-O-M to verify that there is power at the ‘LO OTHER COMPONENTS WILL BE REQUIRED! LlTE(NC)’terminal and no power at the ‘HTR(NO)’ terminal. • Remove the jumper wires from the ‘RESET’ termi- nals. SEPTEMBER 2, 2014 M24E & M36E ELECTRIC BOILERS...