2-12
F3 LIMITED. Change current building mode to limited.
F4 CLOSED. Change current building mode to closed (takes approximately one minute to
complete). If a device input point configured to prevent building closure is active, the building will
remain in the limited mode until the point is cleared.
Full Screen Monitoring
Displays system logs in a manner similar to the review transactions feature (see Review
Transactions—Full Screen in this section) except that new transactions display as they occur. Use
F8 to toggle between full and half screen displays.
MISCELLANEOUS INFORMATION
Disk Almost Full Warning
This feature warns operators when the disk drive has reached a specified percentage of its total
capacity:
When the warning appears, take immediate action to reduce the amount of data stored on the disk
(delete unwanted files, etc.).
This feature uses the DISKWARN keyword parameter located in the $DATAPATH/PARAMS.M
file:
Parameter
DISKWARN keyword missing
DISKWARN =0
DISKWARN =n
N
OTE
Section 6, Transactions [tranentr]
Default Condition
—
Defaults to 90%
—
Feature disabled
—
Feature enabled; n is the range 1—99
S
2: M
S
ECTION
ONITOR
ECURITY
A